ABB 1SDA073130R1 1SDA073130R1 ABB E4.2N 3200 Ekip G Hi-Touch LSIG 4p WMP View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA073130R1 ABB E4.2N 3200 Ekip G Hi-Touch LSIG 4p WMP

1SDA073130R1

073130

ABB

1 Pcs.

E4.2N 3200 Ekip G Hi-Touch LSIG 4p WMP

Automation > Power circuit-breaker for trafo/generator/installation protection
E4.2

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

A four-pole withdrawable air circuit breaker, the 1SDA073130R1 ABB E4.2N 3200 Ekip G Hi-Touch LSIG 4p WMP produced by Abb, offers sophisticated protection for heavy industrial switchgear assemblies. This component manages high continuous operating currents while safeguarding complex electrical distribution networks from transient faults.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
  • End Of Life Disassembling Instructions: 9AKK108468A2363
  • Environmental Product Declaration - EPD: 9AKK108468A1904
  • Extended Product Lifetime: Lifetime Extension Services are Offered
  • Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.3 %
  • REACH Declaration: 9AKK108466A1425
  • RoHS Declaration: 9AKK108466A1424
  • RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
  • Toxic Substances Control Act - TSCA: 9AKK108467A8326
  • SCIP: 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
  • Environmental Information: 9AKK108467A6707
  • Order Code US and Canada: ZCNVENAQ200A000000XX
  • EAN: 8015644769802
  • Minimum Order Quantity: 1 piece

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
ABB Site Meeting Group Waste To Landfill TargetUL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions9AKK108468A2363
Environmental Product Declaration - EPD9AKK108468A1904
9AKK108468A1910
Extended Product LifetimeLifetime Extension Services are Offered
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 79.3 %
Material Compliance
REACH Declaration9AKK108466A1425
RoHS Declaration9AKK108466A1424
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
Toxic Substances Control Act - TSCA9AKK108467A8326
SCIP5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
Environmental
Environmental Information9AKK108467A6707
Ordering
Order Code US and CanadaZCNVENAQ200A000000XX
EAN8015644769802
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width551 mm
Product Net Height425 mm
Product Net Depth / Length383 mm
Product Net Weight74 kg
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width515 mm
Package Level 1 Height610 mm
Package Level 1 Depth / Length785 mm
Package Level 1 Gross Weight81 kg
Package Level 1 EAN8015644769802
Additional Information
Product Main TypeSACE Emax 2
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
VersionW
Technical
Connecting Capacity3000 mm²
Current TypeAC
Electrical DurabilityUe =< 440 V 7000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu])100 %
Number of Poles4P
Power Loss743 W
Rated Current (In)3200 A
Rated Impulse Withstand Voltage (Uimp)acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)AC 1000 V
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(660 V AC) 66 kA
(690 V AC) 66 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)100 %
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 66 kA
for 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 66 kA
(525 V AC) 66 kA
(690 V AC) 66 kA
Rated Uninterrupted Current (Iu)3200 A
Rated Voltage (Ur)690 V
Recommended Screw DriverM12
ReleaseEkip G Hi-Touch LSIG
Release TypeEL
Short-Circuit Performance LevelN
StandardsIEC
Sub-typeE4.2
Suitable for IT NetworksYes, 690V
Certificates and Declarations
Data Sheet, Technical Information1SDC200023D0209
Declaration of Conformity - CE9AKK106713A5545
EU Data Act Compliance Declaration1SDH002560A1001
Instructions and Manuals1SDH001000R0002
Instructions and Manuals (Part 2)1SDH001316R1002
External Classifications and Standards
ETIM 9EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)4926 >> Air circuit breakers
Object Classification CodeQ
UNSPSC39121615
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)
eClassV11.1 : 27370409