View larger
1SDA071849R1
071849
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | e840a757-79d4-433c-becb-befef0cf5de5 Italy |
| Simplified SCIP | 3c752492-6780-43a9-ab90-7df5336a33b9 Germany |
| b7693a2b-9e1e-4c2b-b76c-c1ea553e1888 Bulgaria | |
| a790348d-a32b-4663-a693-94dd9b75abd9 Poland | |
| 2d30d583-8b5f-43e5-944d-a705503d1f17 Poland | |
| 7f94984a-d7c9-49fd-88d3-b57eaa478315 Portugal | |
| ed469b8b-48fd-4eeb-9df9-b38180a75b43 Sweden | |
| 77d2a5ad-a697-4281-92bb-ceb9ae12db96 Norway | |
| 07622b67-f6b9-42e8-8e67-0999710371f6 Poland | |
| 4668af59-b224-4959-9564-deeda1c7f11b Hungary | |
| 20d79be9-dcba-4744-b67e-377814986f4d Czech Republic | |
| f4813d70-46ea-4395-a1e7-0f4842085892 Denmark | |
| df611ba4-8860-4c5e-9e20-d1051664b8c3 Germany | |
| 705ef5b9-cde7-4c48-a1f6-c682d51d352e Germany | |
| 0eed01c8-043d-4231-be7d-980670ee308d Germany | |
| 38e9b6f6-85d6-46c9-a9fc-5fe14f601d30 Germany | |
| ad1d749d-cfb7-4563-b55a-fc385522fbd0 Estonia | |
| 3ebc82e7-7054-4f21-96af-9503f2eb0b0f Belgium | |
| dc19277e-7a04-486d-b846-3894506dff20 Sweden | |
| e4dc5840-1e13-40db-a6e3-b58fbb996be6 Netherlands | |
| 77a2a1eb-77b7-4a71-923d-7b7608de45d3 Finland | |
| 87aac934-fe62-4f1c-ad41-5359f0352393 Greece | |
| 9eea0471-2012-4cbe-919c-afd705ba777d France | |
| caa2c70e-04a7-4296-848e-7eeea29b4fe2 Croatia | |
| 037a6307-9348-407e-b486-e6c1ed1c6a55 France | |
| 330b7d53-9a8c-47ab-ac22-83e96bf27b44 Hungary | |
| cbb5c1cb-9666-419f-a956-f97c37f8ccf8 Belgium | |
| 8eb525a4-9e53-49f4-97d9-61726f0db277 Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCHWERBK200A000000XX |
| EAN | 8015644756994 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644756994 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 4000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 5000 cycle |
| Ue = 500 ... 690 V 4000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 15000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 465 W |
| Rated Current (In) | 4000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 75 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 4000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 4000 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 100 kA |
| Overload release current setting (EF002336) | 1600.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 2400.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 6000.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Bolt connection |
| Device construction (EF008240) | Built-in device fixed built-in technique |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Back |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |