View larger
1SDA071798R1
071798
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2363 |
| Environmental Product Declaration - EPD | 9AKK108468A1904 |
| 9AKK108468A1910 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.3 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 9d176fac-e423-4c28-be3f-ecdce558cc7d Italy |
| Simplified SCIP | 29e835be-2467-404b-80b6-a316a5d8fe39 Germany |
| 2fb1705c-ae7f-40d8-bba9-5d9c73685f1c Czech Republic | |
| 90efdeb2-b283-4983-9e03-38d13d88e73f Hungary | |
| e92baac9-a576-434b-976b-6d327b3f5848 Norway | |
| 141df488-3458-49b1-baeb-61b6bedb3bcf Poland | |
| a871fbc2-9b5b-46a3-90c9-2ff87ed23518 Croatia | |
| 7aeba3ba-99e2-407a-b8e2-233261148760 France | |
| 687ded11-f7e4-4955-97b8-8ee98b36dd1b Germany | |
| a848bb63-dca6-4184-b027-39f03a3c9a4e Denmark | |
| b275fb27-e01a-4e1b-8c84-891ed735034d Germany | |
| 0c399ff1-cf11-48c5-b80a-1eeffeca1805 Netherlands | |
| a1c9b47c-e98a-42d3-b2b6-cd39968bd176 Greece | |
| 0eb2a150-e92a-4360-ab02-a24e6aee0a47 Estonia | |
| 789d1956-e40f-4cc9-91fa-0b2854fc8de2 France | |
| d2bde273-90ec-40d7-9436-c03b86ea1a2e Finland | |
| 25b6adb0-8705-4db2-94dc-40d7e4175929 Belgium | |
| 4b806aef-e9c6-4807-8b7f-aa8b7c3357d2 Sweden | |
| 5806c60e-b35c-431d-b979-fb55e7a91662 Germany | |
| e39437fa-171f-4c4d-a04f-95c3bc7f7389 Germany | |
| 66afbb2e-54a1-4fa3-9142-e3743982684d Portugal | |
| d468ca6d-b1e4-4d75-a7a2-8455609222e8 Bulgaria | |
| 5cf882a8-ebd6-44e1-85c3-521c77f7ab87 Sweden | |
| 3f37c7f2-59bf-464e-a343-b22e7f8e1e67 Poland | |
| 082e5152-4d8d-4c56-85ce-0b672d0fc8cc Poland | |
| d8c8c7ce-4135-496d-a2b3-4ae5d0901b1b Belgium | |
| 32dc418a-bb68-4487-83a0-f74d76947956 Spain | |
| 01a1bf07-5fd9-4d7b-8f16-b039db5822f5 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZCHVENBJ200A000000XX |
| EAN | 8015644756482 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 510 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 70 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 785 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644756482 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0197 |
| Technical | |
| Connecting Capacity | 3000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 7000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 425 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E4.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5545 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001001R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 4. Large Equipment (Any External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |