View larger
1SDA056322R1 ABB E3S 3200 PR121/P-LSIG In 3200A 3p W MP
1SDA056322R1
056322
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for high-capacity electrical grids, the 1SDA056322R1 ABB E3S 3200 PR121/P-LSIG In 3200A 3p W MP air circuit breaker provides reliable fault interruption and circuit isolation. These withdrawable units are standard in large industrial plants to protect primary transformers and main distribution lines.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 5a987b5c-7683-49ad-a29b-31efd4f5aee7 Italy
- Simplified SCIP: f6aff4b1-68eb-4608-bda0-0642b97ffa27 Bulgaria
- Environmental Information: 9AKK10103A6076
- EAN: 8015644576622
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 5a987b5c-7683-49ad-a29b-31efd4f5aee7 Italy |
| Simplified SCIP | f6aff4b1-68eb-4608-bda0-0642b97ffa27 Bulgaria |
| 5619d7b3-8b90-4a5b-9e14-6e56dda4b089 Poland | |
| 58eb8bc5-d8b1-44ea-a5c4-dc3eb6936047 Belgium | |
| 21b2dffc-8301-4d76-9bda-bac5b893d24c Croatia | |
| 4a84d7c4-4a09-456f-98cb-2cca2a5b6631 Netherlands | |
| 83ab245d-8f96-4d11-9126-0b714be8bf1e Germany | |
| 81e3730c-0b8b-43d1-b66a-8808a11c5f31 Czech Republic | |
| e0db24a1-13c0-46dc-a615-11dd10306722 Germany | |
| b403883e-0b66-4391-b64b-33cbb9c686ab Germany | |
| 917c331e-45c2-4dd3-bb06-5111200e66a0 Finland | |
| 86cb1ed2-32bf-4ea0-85d5-58d15358deec Denmark | |
| c593d584-a4f2-4286-bf86-b871bdb4f422 Norway | |
| 055cc049-b7b8-4a17-bdfd-75a67434c5ab Poland | |
| a0bca91a-945f-40c5-bad5-d38519d0522c France | |
| dfec80fd-ca1a-4992-a515-6a8df53891bc Hungary | |
| b9291344-b291-45cd-91d6-a227a1e9279c Germany | |
| 4a594ebb-93ce-40c5-b15e-30107fe4735e Sweden | |
| 6e43d772-a5aa-4fab-8be5-e2ef0ff20bbd France | |
| 05c673ab-dd63-43dd-9f41-07cb97bd3578 Hungary | |
| e83a4c07-3917-45ad-a55b-c7a89108feb1 Belgium | |
| eda4fa17-8da5-4d1a-9e13-5115003eeb9b Poland | |
| 77eddf38-4691-40b9-a9bb-c3bd181d0732 Estonia | |
| 1ba49059-5066-4fd6-a00c-850fa69b5594 Germany | |
| 0ad6ea80-9f3f-46c2-8d47-e42a5e7d637f Greece | |
| 909381bd-03fc-4622-b5b4-9efc6643906b Portugal | |
| e108cd26-b952-45e3-b032-1a2456aebb7b Spain | |
| 24d04a95-29e8-411c-beac-1d6b3dfece72 Sweden | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644576622 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644576622 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 6000 cycle |
| Ue = 500 ... 690 V 5000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 570 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 3200 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |