View larger
1SDA056260R1 ABB E3S 2000 PR122/P-LSI In 2000A 3p W MP
1SDA056260R1
056260
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA056260R1 E3S 2000 PR122/P-LSI is a 3-pole air circuit breaker deployed in industrial power distribution systems for reliable circuit protection.
Power switchgear utilizes air circuit breakers to interrupt high fault levels and maintain uninterrupted operation across complex electrical networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 60a72c34-b1fe-4e72-aef1-b64ffef0e969 Italy
- Simplified SCIP: 6904e75f-ce61-4dc8-9cb7-15d7320dfd1a Sweden
- Environmental Information: 9AKK10103A6076
- EAN: 8015644576004
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 60a72c34-b1fe-4e72-aef1-b64ffef0e969 Italy |
| Simplified SCIP | 6904e75f-ce61-4dc8-9cb7-15d7320dfd1a Sweden |
| 0004b232-214f-4ec5-a742-6c89ae14d799 Bulgaria | |
| edf9fdb6-acc8-4de1-8f78-0ee14520ca92 Spain | |
| abe90ede-e454-43f4-be24-7fc4ac4bcbc5 Portugal | |
| c1953f42-6bb4-4d43-b37f-ebe38573fa89 Poland | |
| 44c01cd1-5354-42de-9606-b5f28d9e1990 France | |
| d36a1d05-a3b6-48e0-9c78-c71410014cb9 France | |
| 854b7162-3d64-42ee-b2db-3fc534e9c2b6 Sweden | |
| a32107b0-19aa-4bfd-b9ba-85dbbd225817 Hungary | |
| 9b184088-b684-4952-85c2-90aa320b9fc6 Belgium | |
| 2ec461a1-0972-4afd-966e-cda274fe0248 Greece | |
| e52ec303-d0df-4e69-99b3-391e7668739d Germany | |
| 18a4b9f8-d16f-451b-92fc-57d43a2df936 Estonia | |
| c0f43b43-e4a7-4343-820e-5a19d041e92b Germany | |
| b61c40cb-756c-4845-ad48-26d301992059 Germany | |
| d5dd748e-063a-412e-ad6a-d25967e13d5c Czech Republic | |
| cc7cd75c-3439-464f-b986-388008ca751c Netherlands | |
| 9af33315-f6e3-4142-a11f-942cd0f0875a Poland | |
| 9d1f0be3-ebc5-4cd5-9361-338db140a3d4 Norway | |
| 41ddf237-4cf7-4e68-9bd8-fa52613d4243 Croatia | |
| 590ab225-7779-403c-bc4d-7b96ac039552 Belgium | |
| f44b911a-3c60-4f26-bd39-7cee09ec254e Hungary | |
| e5f5e4d8-ff85-473d-b34b-e0fb2be91a26 Germany | |
| 8cbe3d85-a4ee-4ef6-929f-7df74f3ea876 Denmark | |
| 27b31c82-254c-4646-858f-d73f4a3b354a Germany | |
| 737c1970-ff64-4fc9-adcf-99e0babd4bcc Finland | |
| 83de419d-72b9-41f4-85e5-dd1ffc107d45 Poland | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644576004 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644576004 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 9000 cycle |
| Ue = 500 ... 690 V 9000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 225 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |