1SDA056241R1 ABB E3S 2000 PR121/P-LSI In 2000A 3p F HR
1SDA056241R1
056241
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA056241R1 ABB E3S 2000 PR121/P-LSI In 2000A 3p F HR is a heavy-duty air circuit breaker designed to manage and protect high-capacity electrical distribution systems. Industrial installations rely on these switching devices to safely interrupt high fault currents, prevent equipment damage, and isolate circuits during maintenance. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 94f4efcd-f557-4b8a-99c2-80b4ca305de4 Italy
- Simplified SCIP: 6bfa567a-1604-4001-9c2e-4d39aaaad6cd Netherlands
- Environmental Information: 9AKK10103A6076
- EAN: 8015644575816
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 404 mm
- Product Net Height: 418 mm
- Product Net Depth / Length: 302 mm
- Product Net Weight: 60 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 94f4efcd-f557-4b8a-99c2-80b4ca305de4 Italy |
| Simplified SCIP | 6bfa567a-1604-4001-9c2e-4d39aaaad6cd Netherlands |
| c458b0e9-2219-4bfd-8379-4514322ea5e4 Sweden | |
| 1f3f901a-45a9-4001-9d22-040510a66b29 Germany | |
| d327bbfc-2d9c-4ae2-bea2-bcbe8a363496 Hungary | |
| 322e52c6-ce63-4a13-b050-578129dc99a1 France | |
| 009423ed-0832-4e88-a842-a99af3871bb8 Germany | |
| fa8dd535-9cdd-4cff-be1f-ca4a2c4a9f1e Belgium | |
| 459f27e0-3c30-447f-a8be-b393fdca25db Spain | |
| 2b78dae4-009d-4d77-9e62-191389811186 Poland | |
| f545bc57-7860-42b4-8b16-8bd7a6b6753e Germany | |
| beade655-8e69-4762-a469-536c93414e00 France | |
| 2bc45aa3-a0ff-49f0-8663-fa72174cc7a3 Poland | |
| 69adb2b9-1e0f-4e16-adf1-6ce1f71c2d57 Norway | |
| 27bff479-06f7-4fb6-a464-fae5f9d58d02 Sweden | |
| d12a154c-7867-45be-afa3-670281ef60e9 Finland | |
| 09ee82f4-6f48-4a13-8390-8d196527701a Belgium | |
| fa13e9cd-efa5-4a4b-baa4-d73fcbed5c13 Germany | |
| a99140dc-2cc3-487a-acf4-51d51da9dde4 Germany | |
| 4eeb800f-f223-418a-a7b7-9099aa7a0b4c Poland | |
| 81c263f8-a59e-4c8a-941c-b48a6eb2b8d7 Denmark | |
| 6cfd11a7-5399-43ac-a26f-c494e0986f34 Portugal | |
| 9589116a-b966-41c9-8135-b13b0f9d6590 Bulgaria | |
| 5c0efa79-ec1d-4991-b83d-de4f26edeae6 Croatia | |
| 4036328e-2966-467d-9a3f-1df19bd874de Greece | |
| 38d33cd6-a8eb-463f-9339-623a779c49b8 Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644575816 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 404 mm |
| Product Net Height | 418 mm |
| Product Net Depth / Length | 302 mm |
| Product Net Weight | 60 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 72 kg |
| Package Level 1 EAN | 8015644575816 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 9000 cycle |
| Ue = 500 ... 690 V 9000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 130 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Rear flat Horizontal | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |