View larger
Images are for illustrative purposes only. Please refer to data sheet for details
1SDA056256R1 ABB E3S 2000 PR121/P-LI In 2000A 3p W MP
1SDA056256R1
056256
ABB
1 Pcs.
E3S 2000 PR121/P-LI In=2000A 3p W MP
E3S2000 PR121/P LI 3P W MP
Automation > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SDA056256R1 is a heavy-duty withdrawable air circuit breaker designed for primary power distribution in industrial plants. These components manage large electrical loads and protect systems from severe overcurrent conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 9a512a9d-c1af-49d8-b32d-b3fa772e46b0 Italy
- Simplified SCIP: 14dec237-bcbc-43ca-9f29-b2e7039b8d35 Poland
- Environmental Information: 9AKK10103A6076
- EAN: 8015644575960
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 9a512a9d-c1af-49d8-b32d-b3fa772e46b0 Italy |
| Simplified SCIP | 14dec237-bcbc-43ca-9f29-b2e7039b8d35 Poland |
| 88fe6ced-b24a-48cf-9fc8-e08125595e7f Bulgaria | |
| 37f3258a-8a25-4f51-9996-23cf15cc5b47 Sweden | |
| 01f2a668-c314-43fd-abbf-a8a5943bdca3 Germany | |
| 83078b1f-f27e-4ec0-8e0c-54d52d5abded Estonia | |
| 006c6388-1c53-4063-9627-375073c838a3 Greece | |
| 8d90f255-454c-4295-ba10-05ab5447e86e Portugal | |
| 60810e41-2e49-4d25-9a95-5fa81a37e5ec France | |
| b8a3a8e6-717d-4a35-b545-4457883a5a8d Spain | |
| 4cab71a1-328a-4a3a-b0c6-16656eec2dec Germany | |
| 776013f6-9a79-4485-ab09-8f3c21e0ac24 Belgium | |
| 30327052-5097-4551-916c-cc998d178464 Hungary | |
| 78188bac-7c8d-484d-bfc7-cf8131f50dfa Sweden | |
| 5a8cce48-d91c-4071-9c3b-d39834b29676 France | |
| ef523e1e-b37c-40f8-826f-162a34a0fc10 Poland | |
| 996870c5-d2f0-424e-b1c6-d893314858b7 Belgium | |
| 9c4e2028-b3df-4af4-b0f5-8c1922dd921a Germany | |
| 03ef49cf-5ccf-4da8-be14-258db0d73513 Czech Republic | |
| ea87299b-4351-4a6b-a93e-968ce9f9589a Denmark | |
| 61a7cb94-a1c5-423d-920f-a53e445f13c5 Norway | |
| fd42be81-847b-4cf1-8242-198bbd0e3a3a Germany | |
| 282eb288-21a5-4748-987a-a6e0ce2cab40 Netherlands | |
| ff9801ee-6399-4b45-9bfd-ad503424263c Croatia | |
| 5bebd74f-052f-4ecf-98d5-050f9acd3662 Poland | |
| 5116488b-7c4d-444a-92c3-9ea391a90713 Hungary | |
| 0afaf402-9182-4273-b3fc-4a857632af28 Germany | |
| 070da055-5a3d-4357-b8c8-1ff26af6f3ba Finland | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644575960 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644575960 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 9000 cycle |
| Ue = 500 ... 690 V 9000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 225 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2000 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |