View larger
1SDA056225R1 ABB E3S 1600 PR121/P-LSI In 1600A 3p W MP
1SDA056225R1
056225
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA056225R1 is an advanced air circuit breaker part designed for secure draw-out installation within complex switchgear assemblies.
Industrial installations rely on such withdrawable circuit breakers to manage massive electrical loads and facilitate safe maintenance operations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 7713908b-71b9-468f-bffa-740ab84f4a53 Italy
- Simplified SCIP: 2dcb1585-dc54-48d2-ae9c-5b5e3ffc185a Denmark
- Environmental Information: 9AKK10103A6076
- EAN: 8015644575656
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 7713908b-71b9-468f-bffa-740ab84f4a53 Italy |
| Simplified SCIP | 2dcb1585-dc54-48d2-ae9c-5b5e3ffc185a Denmark |
| d6f13887-b414-4d4b-a215-c328a4f5b385 Germany | |
| af79027c-6296-4a7b-a4ce-1d269ce9bc4d Finland | |
| f598af81-0224-46cc-9b33-5fddc06c7527 Poland | |
| 8e20d146-83a1-4e51-8a88-76492d6fb911 Germany | |
| d0574ad6-abe5-4e33-9702-c51f3fba5db9 Norway | |
| 53c223da-f343-47bd-8a3d-32ac3c86a5f6 Croatia | |
| 9be025b7-caba-45f7-ba04-0d5c14321fdf Belgium | |
| fda390aa-7c0c-473b-8dcf-622f9a4fe521 Hungary | |
| 0ef282b4-d06d-47ea-a06c-f7781f066a3b Netherlands | |
| f0c916fd-204d-4084-95ec-917f864805c6 Poland | |
| 5ae8d92a-f584-4cc2-9923-82223554bbbd Czech Republic | |
| 381a8789-b754-41ed-9101-b853541251d4 Germany | |
| 61b01012-1805-4037-8458-0dc56cc0474f Portugal | |
| fdfe649d-1d1e-475e-adeb-82e738c9a800 Spain | |
| 5a502a45-e64b-481c-a634-c6f3ea00b180 Germany | |
| 52c4054c-2235-4a7f-bd17-7d217a07a6db Hungary | |
| 1de4f832-1aac-454c-8e28-41c99c44978c Belgium | |
| c734ba3b-cae0-498c-ae6e-d7b3360deefc Greece | |
| 5524d9c9-0492-4420-bc32-bfeed8516296 Bulgaria | |
| 56be9d83-18da-486a-a1f1-6ce592114446 Sweden | |
| b904fdf6-0433-4cab-8e13-a642312606a2 Estonia | |
| e164a4d4-7e95-43ab-91a1-207e4a676d85 Germany | |
| 0d9bc815-6f0c-451f-9b56-2aa4a113a0e3 Poland | |
| a362833b-2ae4-475a-a787-3dd84b3d07b0 Sweden | |
| c5575275-3118-4152-abc7-ba7d2c25f410 France | |
| 22c2d29f-33d4-429c-b3b0-7c07c2e416ef France | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644575656 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644575656 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 150 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1600 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |