View larger
1SDA056192R1 ABB E3S 1250 PR121/P-LI In 1250A 3p W MP
1SDA056192R1
056192
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This ABB 1SDA056192R1 ABB E3S 1250 PR121/P-LI In 1250A 3p W MP is a withdrawable air circuit breaker engineered for primary power distribution and heavy industrial switchboards. Units of this category provide robust short-circuit interruption and selective coordination for high-demand electrical systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 3d7fcec7-032e-47b2-940f-7d9f7fde5287 Italy
- Simplified SCIP: b839b9d6-7c4b-47a7-90e7-7f599df84b2a Poland
- Environmental Information: 9AKK10103A6076
- EAN: 8015644575328
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 3d7fcec7-032e-47b2-940f-7d9f7fde5287 Italy |
| Simplified SCIP | b839b9d6-7c4b-47a7-90e7-7f599df84b2a Poland |
| c1cc424e-c8cd-4ee6-adec-66939e7884e6 Poland | |
| 04669f7d-59e3-451a-b247-c5819b8d2166 France | |
| 36fc7011-822d-495e-9059-fe9a7b850404 France | |
| ff4bfb5e-c206-4f0d-acdd-c994ae2ff38f Sweden | |
| 1220e517-47f4-44be-abdd-cc51384a405e Spain | |
| cf68bccd-5caf-4a0b-8ccf-b0f028ee94ce Portugal | |
| 45a54e6a-743b-48fc-83c1-16cfa4dab38e Bulgaria | |
| 22de3f4f-fdc2-4470-9685-a5ef1abeda86 Sweden | |
| 2a563bc2-1d23-4918-8178-59bdeeab2915 Germany | |
| 9c79d8b7-9160-4cfd-9ddc-ad579b5a3ab5 Greece | |
| 29132207-51ef-4b34-adc0-f5ef9be33677 Germany | |
| 72b09d30-b9f7-4a04-ae70-43adfbbd8eff Estonia | |
| acf39b15-0895-4ac8-8426-aa35f75a7c6c Hungary | |
| dd511ea8-3f23-430f-af40-e18a295111b9 Belgium | |
| 7926d577-6bae-4178-9fd2-660ef2c54fd4 Denmark | |
| fec5749b-0f0c-4823-8e85-bb40749b5c9d Germany | |
| 25608b8a-b977-4211-8905-d96ec5272b41 Finland | |
| 24608de2-a68b-4679-9da0-bc3258e1d1dc Poland | |
| b2e30228-67d3-4925-9f10-6772a428e9e0 Germany | |
| 00c46713-e63a-4411-8e70-42c4a5cd1f86 Croatia | |
| 38685904-2a98-45a0-ac60-39053606a502 Hungary | |
| d7a9186b-d05e-4687-b775-5c16c066323c Belgium | |
| 5574c431-1010-42f0-96ee-7da4c1c390c9 Netherlands | |
| 5fe5dd58-a268-4c9c-8c18-6767eb69444e Norway | |
| 6c6e294c-92e3-48fb-92d9-c77120c754e8 Germany | |
| 40de98be-e697-44b9-b7a0-54813791f48a Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644575328 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644575328 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 12000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 90 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1250 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 75 kA |
| (230 V AC) 75 kA | |
| (380 V AC) 75 kA | |
| (400 V AC) 75 kA | |
| (415 V AC) 75 kA | |
| (440 V AC) 75 kA | |
| (500 V AC) 75 kA | |
| (660 V AC) 75 kA | |
| (690 V AC) 75 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |