View larger
1SDA056148R1 ABB E3N 3200 PR122/P-LSI In 3200A 3p F HR
1SDA056148R1
056148
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Heavy electrical installations rely on high-capacity air circuit breakers like the ABB E3N 3200 PR122/P-LSI In 3200A 3p F HR to protect major incoming power feeds. These units provide dependable fault clearing capabilities and electronic trip monitoring to maintain uptime across industrial power networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 17016799-d248-4de9-ab81-ae92bffa1f77 Italy
- Simplified SCIP: 3ec3bfdb-3ed1-42fb-b59e-c800cda1862d Spain
- Environmental Information: 9AKK10103A6076
- EAN: 8015644574888
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 404 mm
- Product Net Height: 418 mm
- Product Net Depth / Length: 302 mm
- Product Net Weight: 60 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 17016799-d248-4de9-ab81-ae92bffa1f77 Italy |
| Simplified SCIP | 3ec3bfdb-3ed1-42fb-b59e-c800cda1862d Spain |
| 09bf24a7-d010-41e4-916c-b84c825ee235 Sweden | |
| 8c4b95be-6af9-45b0-b727-2203692f11e7 Finland | |
| 7e2e35ff-eb13-4249-a9bb-6bf43a307732 Belgium | |
| e841489a-1724-496c-b2c4-96365c49dd4d Poland | |
| 0a162585-2b7f-4b79-847d-943409456f95 Germany | |
| 1bb63ac8-7eaa-411e-8d9c-b511860f9c54 Germany | |
| ac48e7b7-b72d-4dd5-8257-c2c5b210ea86 Denmark | |
| f8a02d5e-e0a2-4ef9-a25c-1cc1b9fab808 Czech Republic | |
| 18265737-cb4b-42f9-9b66-70c900bb2f49 Croatia | |
| 38655c19-ed89-4b9a-93bd-4cdb1b9927c4 Greece | |
| 23e45bd2-5b06-4c23-8c33-13fab99a7d34 Bulgaria | |
| c3b715fd-81f9-405e-872d-070aabc990e6 Netherlands | |
| 63704c9a-2bf6-4aae-89b1-db9f1769e618 Hungary | |
| e6af3780-80b7-4d95-97d9-5f356ad02012 France | |
| 7a8178f8-b72b-4ac7-90bc-2518c763ca8b Sweden | |
| c8044918-e28c-4a58-806e-a20d10c48d86 Germany | |
| 71819eea-4380-459a-b25f-60ccd757bee5 Germany | |
| 33a40e65-6f7c-47c3-86bf-fa987ec6b826 France | |
| 738661c8-827f-4a59-89fd-1880cffb574b Poland | |
| 073a706f-23b2-4998-99be-c9e847edd393 Germany | |
| 9e7e88c4-5beb-41c2-bd10-11820596af0d Norway | |
| cf0f5bea-da67-4ee2-b253-98db47451c01 Poland | |
| 2b9d1bec-2c4c-49df-9337-02025f8fcf66 Belgium | |
| f80a0775-0f11-4af7-87b5-66a8662dd895 Portugal | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644574888 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 404 mm |
| Product Net Height | 418 mm |
| Product Net Depth / Length | 302 mm |
| Product Net Weight | 60 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 72 kg |
| Package Level 1 EAN | 8015644574888 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 6000 cycle |
| Ue = 500 ... 690 V 5000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 330 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 3200 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Rear flat Horizontal | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |