View larger
1SDA056161R1 ABB E3N 3200 PR121/P-LSI In 3200A 3p W MP
1SDA056161R1
056161
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA056161R1 E3N air circuit breaker provides reliable fault interruption and load management for major industrial electrical distribution systems. Heavy manufacturing facilities utilize these components to maintain continuous operational safety during heavy power demands.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: dc48e105-d1cc-4924-ab92-0043729a1394 Italy
- Simplified SCIP: 637dcebb-2965-4ab3-a639-522551114118 Poland
- Environmental Information: 9AKK10103A6076
- EAN: 8015644575014
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | dc48e105-d1cc-4924-ab92-0043729a1394 Italy |
| Simplified SCIP | 637dcebb-2965-4ab3-a639-522551114118 Poland |
| ada170b2-2604-4296-b251-0ed7e8ead423 France | |
| 3f1833e1-62f2-4256-8035-a88bea83f9ce Sweden | |
| c285ede6-4425-4c23-a78a-a57cf91e8657 France | |
| b6cf3d52-4de4-426c-95ae-1aabbdd40f7d Spain | |
| 8161f407-8384-4157-91c2-37e685cf961f Germany | |
| 29058293-76fe-4da5-9d32-d9b0d959bede Hungary | |
| 12e2f7ad-a6dd-4438-b0ce-3bfa49dea253 Belgium | |
| ac71233a-53a3-4669-8132-1936cc707b49 Germany | |
| dda17654-b3db-4d48-8116-fa2b4788d797 Estonia | |
| 2dfb54b4-01d2-43f6-bb29-a1e99d8d1bdf Sweden | |
| 3db47c4c-7c9a-48e5-b015-1ae0c599fa95 Greece | |
| d11f5f85-9324-4f59-b974-84f3171b5bb3 Portugal | |
| 3aa865f1-a573-4799-b264-732914bfc3ed Germany | |
| 707e1455-68cd-4634-aa2f-48df5564d2fc Bulgaria | |
| b93d1dea-a6ac-4909-a2f0-56ec47f04f88 Poland | |
| 50423472-de03-4255-97b9-ef27188d2c5f Poland | |
| 004015dd-3ac4-4839-a781-6b3c9eff9a36 Finland | |
| 098414db-63d5-44e4-a7c6-69922a9b025d Denmark | |
| 8c17522e-652e-41f0-9497-2d712bae137d Norway | |
| f8b5d695-19b7-460b-a2da-1624857737fa Germany | |
| c837d554-2baa-4dd7-a3bd-9a7ec7541bde Czech Republic | |
| 1f1c5b27-092b-4bc1-9ba5-2ffcdd3d398d Belgium | |
| 06370f18-db84-4d5d-b894-cda118b78086 Germany | |
| 9ba4a223-500f-46bf-9bcb-42b2a164288e Netherlands | |
| 166f4312-4dd3-4c72-8dd8-8b8800ad971d Croatia | |
| b2c9a20e-d49a-4e85-a282-f4ede60609c2 Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644575014 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644575014 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 6000 cycle |
| Ue = 500 ... 690 V 5000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 570 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 3200 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 65 kA | |
| (660 V AC) 65 kA | |
| (690 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |