ABB 1SDA056364R1 1SDA056364R1 ABB E3H 800 PR122/P-LSI In 800A 4p W MP View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SDA056364R1 ABB E3H 800 PR122/P-LSI In 800A 4p W MP

1SDA056364R1

056364

ABB

1 Pcs.

E3H 800 PR122/P-LSI In=800A 4p W MP E3H800 PR122/P LSI 4P W MP

Automation > Power circuit-breaker for trafo/generator/installation protection
E3

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Circular Value
Conflict Minerals Reporting Template (CMRT)Document availability on demand
Environmental
Environmental Information9AKK10103A6076
REACH Declaration9AKK108466A1425
RoHS Information9AKK108466A1424
RoHS StatusFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Ordering
EAN8015644577049
Minimum Order Quantity1 piece
Customs Tariff Number85362090
Dimensions
Product Net Width558 mm
Product Net Height461 mm
Product Net Depth / Length396.5 mm
Product Net Weight81 kg
Container Information
Package Level 1 Units1 piece
Package Level 1 Width515 mm
Package Level 1 Height600 mm
Package Level 1 Depth / Length785 mm
Package Level 1 Gross Weight96 kg
Package Level 1 EAN8015644577049
Additional Information
Current TypeAC
Electrical DurabilityUe =< 440 V 12000 cycle
Ue = 500 ... 690 V 12000 cycle
20 cycles per hour
Mechanical Durability20000 cycle
60 cycles per hour
Number of Poles4
Power Loss36 W
Product Main TypeSACE Emax
Product NameAir Circuit Breaker
Product TypeAir Circuit Breaker
Rated Current (In)800 A
Rated Voltage (Ur)690 V
Rated Impulse Withstand Voltage (Uimp)12 kV
Rated Insulation Voltage (Ui)1000 V
Rated Operational Current (Ie)800 A
Rated Operational Voltage690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Short-time Withstand Current Low Voltage (Icw)for 1 s 75 kA
for 3 s 65 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Uninterrupted Current (Iu)800 A
ReleasePR122/P-LSI
Release TypeEL
Short-Circuit Performance LevelH
StandardsIEC
Sub-typeE3
Terminal Connection TypeWithdrawable Circuit-Breakers
VersionW
Certificates and Declarations
Data Sheet, Technical Information1SDC200006D0209
Declaration of Conformity - CE1SDL000165R0015
Instructions and Manuals1SDH000460R0002
1SDH000460R0102
Classifications
ETIM 7EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification CodeQ
UNSPSC39120000
WEEE Category4. Large Equipment (Any External Dimension More Than 50 cm)

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.