View larger
1SDA056513R1 ABB E3H 3200 PR121/P-LSI In 3200A 3p W MP
1SDA056513R1
056513
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Industrial power systems utilize high-capacity air circuit breakers to protect main electrical feeds and distribution boards from damaging fault currents. This withdrawable unit provides reliable isolation and precise overcurrent protection for demanding commercial and utility applications.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 9830ebba-8bb9-4b49-9c46-8cb53c9d83d0 Italy
- Simplified SCIP: 6ba67b7d-2e06-41c2-b227-ed0aa8badd9f Finland
- Environmental Information: 9AKK10103A6076
- EAN: 8015644578534
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 9830ebba-8bb9-4b49-9c46-8cb53c9d83d0 Italy |
| Simplified SCIP | 6ba67b7d-2e06-41c2-b227-ed0aa8badd9f Finland |
| 345284ec-b582-4a94-b653-d5d5d0b66b99 Norway | |
| 73fabcd7-a373-4ecd-9b23-213aef5825dd Bulgaria | |
| 3489a7a3-5291-44a1-b9fc-24893edf4ebd Germany | |
| 35938f8d-3395-4a4e-ab5e-5c3efa59da62 Sweden | |
| 75abe02e-bf56-497c-80d1-71c381ec4807 Estonia | |
| 632bd645-dc93-4629-9fd5-6ed244e695fc Germany | |
| 55bbaf17-bee6-4e29-9ca3-3dd1e3525be3 Portugal | |
| 09a25c52-e437-48c7-a05b-dccc42b848c3 France | |
| 3d7d05d9-6ced-472b-82be-528d34cca2d1 Greece | |
| 2fcd624c-083b-4ab0-8b10-98a9db1e424e Spain | |
| fc60b430-7d4a-497b-b098-8b3b7c434eff France | |
| 3387b98e-0e4a-40d1-a1b9-2bc7c0c7c187 Hungary | |
| 5129053c-01e6-4a48-be6d-75c36817645c Sweden | |
| e781eeb3-7baa-4cec-8848-e584ad5535f2 Germany | |
| 8be4b473-70ca-4916-a229-1c4b24ac3e69 Belgium | |
| 6f4d2643-153d-456f-8666-a0b4b475d9a8 Poland | |
| 06cab3f3-0293-4e90-8b20-ef0ca976e179 Hungary | |
| d198719a-efd2-4805-8b4d-74c28551b9c3 Poland | |
| 793c37ae-91c6-4782-98b3-9e3d6bba7e9c Belgium | |
| 9794c833-b470-4887-a418-8d4e0c05ee57 Netherlands | |
| 0aa49579-b0ed-4d02-b52e-7014175a02bb Germany | |
| 5045c64d-ced1-46f2-9a94-c2f8cd75d85c Czech Republic | |
| 6642a18f-2fa1-4b73-92cd-8872cb42af93 Germany | |
| 8958a462-1cb1-4dc9-b897-01427507cfe4 Poland | |
| 330e323a-37dd-41ab-b684-795457399916 Croatia | |
| fd450d6d-d136-4d9c-8be6-c302cbf2c6d0 Denmark | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644578534 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644578534 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 6000 cycle |
| Ue = 500 ... 690 V 5000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 570 W |
| Rated Current (In) | 3200 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 3200 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 3200 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |