View larger
1SDA056481R1 ABB E3H 2500 PR121/P-LSI In 2500A 3p W MP
1SDA056481R1
056481
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E3
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for heavy-duty power management, the Abb 1SDA056481R1 ABB E3H 2500 PR121/P-LSI In 2500A 3p W MP functions as an air circuit breaker utilized to protect high-capacity electrical distribution channels. These units offer precise electronic tripping capabilities to secure switchboards and prevent electrical hazards in industrial plants.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: e34a9004-b1f6-4533-8710-7d0f32be2516 Italy
- Simplified SCIP: 1f095bc7-0ff6-487f-9bf3-d8a0c461cafa Hungary
- Environmental Information: 9AKK10103A6076
- EAN: 8015644578213
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 432 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 64 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | e34a9004-b1f6-4533-8710-7d0f32be2516 Italy |
| Simplified SCIP | 1f095bc7-0ff6-487f-9bf3-d8a0c461cafa Hungary |
| 189d087f-e469-4c67-bbe7-efbf2528fdaf Norway | |
| a81fdbe3-5614-42a0-8096-1d224fecce0f Poland | |
| 51ff56e3-948c-44de-8a54-c6d86ad230cc Finland | |
| c25a3552-9d3b-41dd-88bb-422564cdc6f3 Sweden | |
| f3c6ff4d-fc38-4924-b1d7-20e0c5339db5 France | |
| 5b8c1c7a-52c1-4caa-9ba3-c1119d9fd693 Hungary | |
| c7ee286d-1bb0-4061-9960-25a41c21254a Germany | |
| 589957c8-b384-47d7-8ba0-905377275cc6 France | |
| 0dc930c0-b8f6-469f-8230-3302b132428e Belgium | |
| 7758252e-1d50-4c36-bb9c-b4397e0eaac8 Sweden | |
| 01b03e2f-c22b-4b22-9a20-bcdbab2214ab Germany | |
| 40fb6a49-9c6c-4bea-8a24-05b9843269ce Estonia | |
| 7e6b15c2-ebc3-4535-91b1-1e49124f1397 Greece | |
| c73b8888-b7f8-4cd0-98da-b852af9e273b Portugal | |
| df29c260-03bd-476b-90c5-87b0e33ef637 Spain | |
| da9d6a9e-6e90-4148-8db7-12470ef45b3f Germany | |
| 3d9a1817-9f14-4bb9-8152-fd4cf53b439f Bulgaria | |
| bc3eb67f-b3e2-4cf5-9132-5f2c6275c70d Poland | |
| 77bd9960-6f19-4c49-9c24-fbab4b853b6d Germany | |
| 4bf5513d-a915-42ed-a302-00164f8241a5 Czech Republic | |
| 560fbeab-224a-403a-8a1b-2569fc7bfb5a Poland | |
| e866b1d9-5d6b-42b6-a01e-4b3ab534a37d Belgium | |
| c9672843-9f57-4599-aea4-652731b83ea9 Germany | |
| 4d516c10-5a26-440a-a172-6357e38b87fb Netherlands | |
| 691ba7ec-fb92-4c28-b7d8-078df97dd59c Croatia | |
| d212fc5c-6a2e-45e2-bdaa-0b7790a4002a Denmark | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644578213 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 432 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 64 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 77 kg |
| Package Level 1 EAN | 8015644578213 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 20 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 350 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 2500 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 75 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 100 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E3 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0015 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |