View larger
1SDA055859R1 ABB E2N 1250 PR122/P-LI In 1250A 3p F HR
1SDA055859R1
055859
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB 1SDA055859R1 E2N 1250 PR122/P-LI In 1250A 3p F HR functions as an air circuit breaker designed to manage and protect heavy electrical distribution networks. Industrial installations utilize these robust devices for reliable fault interruption and circuit isolation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 8ac4b703-8fc3-4967-98c6-38d664899bce Italy
- Simplified SCIP: 9025a49e-e00c-4251-b3e9-9e556b8232b3 Bulgaria
- Environmental Information: 9AKK10103A6076
- EAN: 8015644571993
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 296 mm
- Product Net Height: 418 mm
- Product Net Depth / Length: 302 mm
- Product Net Weight: 45 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 8ac4b703-8fc3-4967-98c6-38d664899bce Italy |
| Simplified SCIP | 9025a49e-e00c-4251-b3e9-9e556b8232b3 Bulgaria |
| 491babb3-e2c5-465c-861c-d757fc0f2eb6 Poland | |
| a362fd66-7b09-49c3-9778-aa4e2d2466c9 Poland | |
| e26311df-75b6-4fa2-bcc1-e2854a9e76fd Norway | |
| 0a38cdf8-8df0-421b-98b2-873e02f74655 Germany | |
| ccd8ace2-2ef6-457d-8aec-602820749658 Finland | |
| a8609ec6-35b6-4834-88ba-d10c066d5f1e Denmark | |
| 1584eb15-882c-403d-afd2-7a15fb31a5da Belgium | |
| 6c8427e4-ab8c-41f8-a9c0-6862ba877143 Croatia | |
| 2051da79-d3ed-44b2-b445-caaed73368e3 Hungary | |
| be59090f-e8f3-4abb-a257-53b571d1e7cd Portugal | |
| 4a3417fd-477b-4904-9d9f-772768dfb741 Czech Republic | |
| 3a9e6417-d37b-4db2-9e84-3a1ee0123b67 Poland | |
| f0490082-c217-41f9-a5c2-74d9a3e1d76c Netherlands | |
| 7956f38f-276b-4844-8cf0-cea47dca3c2b Germany | |
| 3857c927-2ba5-45a0-aa10-eb85e307b4aa Germany | |
| 2129e09d-1209-4f50-aadd-7d7af5f0f525 France | |
| 0debaa56-75e8-48be-9269-84b633d4b4f5 Spain | |
| 1e7a36d6-7602-4924-ae06-93053fc009a4 Hungary | |
| 434f540b-4947-4dfd-80f2-1e4481e17051 Greece | |
| 7ccf74b8-c1ca-4e89-a9c4-5c118e11aed0 Belgium | |
| 822bc1c5-4f97-4ced-9bd3-3ff00432a23c France | |
| eb643e75-9194-4702-8191-3fde3c045ff4 Germany | |
| e4b4fc61-e0a8-4bbb-b60e-ad3cde24ec14 Sweden | |
| 6e2592df-ed47-4092-a271-71ae1748a932 Germany | |
| 3e329131-486c-4bc7-8760-0b23f45d6904 Estonia | |
| f192f221-ca97-4eed-942f-bb91c0cff146 Sweden | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644571993 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 296 mm |
| Product Net Height | 418 mm |
| Product Net Depth / Length | 302 mm |
| Product Net Weight | 45 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 55 kg |
| Package Level 1 EAN | 8015644571993 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 70 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1250 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 55 kA | |
| (660 V AC) 55 kA | |
| (690 V AC) 55 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 55 kA |
| for 3 s 42 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 55 kA | |
| (660 V AC) 55 kA | |
| (690 V AC) 55 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR122/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Rear flat Horizontal | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0014 |
| Instructions and Manuals | 1SDH000460R0002 |
| 1SDH000460R0102 | |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |