View larger
1SDA055856R1 ABB E2N 1250 PR121/P-LI In 1250A 3p F HR
1SDA055856R1
055856
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An air circuit breaker, represented by the Abb 1SDA055856R1 ABB E2N 1250 PR121/P-LI In 1250A 3p F HR, is engineered to manage high electrical loads and interrupt severe fault currents in industrial power systems. These robust protective units safeguard heavy machinery and primary electrical distribution panels.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: 81cf5e5f-269a-4af9-8c7f-aab0455da368 Italy
- Simplified SCIP: f48131e8-7fd7-42ad-904a-c3594a6e6445 Poland
- Environmental Information: 9AKK10103A6076
- EAN: 8015644571962
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 296 mm
- Product Net Height: 418 mm
- Product Net Depth / Length: 302 mm
- Product Net Weight: 45 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | 81cf5e5f-269a-4af9-8c7f-aab0455da368 Italy |
| Simplified SCIP | f48131e8-7fd7-42ad-904a-c3594a6e6445 Poland |
| 40f0a475-03a4-453a-89d4-8b78b0c027e2 Netherlands | |
| 1ce38a00-4bc0-466c-8e16-e6eb1880a55b Hungary | |
| a9b68988-03bc-4272-bc18-d422de0a94d7 France | |
| 957e7c9f-4b52-4350-9d80-2bdff7c117b5 Sweden | |
| d5a972e3-63b5-41b1-a52b-53a9ef4d852b Germany | |
| bc8f0686-ebe8-4062-8914-67e151858440 Germany | |
| 3219d3ba-a359-484f-987f-87cbad5b6ea0 Belgium | |
| 60fdf67d-40ca-4ebf-baf4-47d19e359581 Spain | |
| 0afcf0da-6ee0-489a-b680-2c61dbe73680 Poland | |
| 4e690f9a-d1ed-4e6a-b8c9-596f801f8231 France | |
| 7fedadc6-6689-45b6-ab7c-80951c8a2883 Poland | |
| 35545ad0-212b-4747-ac27-80cb31d93bf1 Germany | |
| d63a0bd2-5069-4abc-bdbb-ac8323012520 Norway | |
| e2a6a69f-7f6a-4a64-996d-3dbb1818ea8b Sweden | |
| 97da6a21-07b4-417d-b263-e59bf37862a8 Belgium | |
| 5ce173d7-8323-48cb-9980-bf70877d03d1 Finland | |
| 5b3479ae-08c5-40af-bca4-1236fcf6caf3 Germany | |
| c38246a1-c045-45d9-ab0e-49530d310051 Germany | |
| 7a495a7b-92e1-4e82-aefe-488f3d245ed2 Denmark | |
| 56ab3e20-b283-46b1-855b-a995c9169e0f Czech Republic | |
| f09949d6-edf8-494e-9ca9-e1b394966ace Croatia | |
| 49e7d6e2-05cf-4480-863a-ffc4a4e468ba Greece | |
| c5cb6952-2e79-4b9c-a426-aafdb2ebe804 Bulgaria | |
| af9d42da-1925-48ea-abb0-7fcc657672e3 Portugal | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644571962 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 296 mm |
| Product Net Height | 418 mm |
| Product Net Depth / Length | 302 mm |
| Product Net Weight | 45 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 55 kg |
| Package Level 1 EAN | 8015644571962 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 70 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1250 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 55 kA | |
| (660 V AC) 55 kA | |
| (690 V AC) 55 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 55 kA |
| for 3 s 42 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 65 kA |
| (230 V AC) 65 kA | |
| (380 V AC) 65 kA | |
| (400 V AC) 65 kA | |
| (415 V AC) 65 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 55 kA | |
| (660 V AC) 55 kA | |
| (690 V AC) 55 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2 |
| Terminal Connection Type | Fixed Circuit-Breakers |
| Rear flat Horizontal | |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0014 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |