View larger
1SDA070904R1 ABB E2.2S 800 Ekip Touch LI 3p F HR
1SDA070904R1
070904
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Supplied by Abb, the 1SDA070904R1 ABB E2.2S 800 Ekip Touch LI 3p F HR is an air circuit breaker employed in primary electrical switchboards to manage high currents and protect industrial installations from overloads and short circuits. These high-performance breakers feature advanced digital trip units for precise network monitoring.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: f9b3a8c6-5294-4fef-9ea7-4e141c34cec8 China
- Simplified SCIP: c11929a5-3dc0-4738-8662-9c956721ad2c France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2SPEFBD000A000000XX
- EAN: 8015644747541
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | f9b3a8c6-5294-4fef-9ea7-4e141c34cec8 China |
| Simplified SCIP | c11929a5-3dc0-4738-8662-9c956721ad2c France |
| 7e06acb9-40ee-4472-a84f-83de530af644 Germany | |
| 3c4325d8-54f1-49a6-b528-c13f2da2bb4a Belgium | |
| a1292309-1327-46c2-8010-7de0bb06568f Finland | |
| 65a3154b-5488-4fe6-ae86-12a9c7a1aa2d Germany | |
| 54fe77ca-77fe-4915-a1f5-7cd098425730 Greece | |
| 9f6cfa9a-967e-4fdc-829e-25357ff687f8 Germany | |
| eac8877c-682a-4158-b7ec-fc067c0b9fa2 Belgium | |
| 110edae1-0fa4-4cea-a42b-2d0ab79b0b17 Croatia | |
| da4ea021-d1c0-49cd-8be1-5b36d9c9159c Hungary | |
| 88b26399-e79d-49ac-ad26-72df34096387 Poland | |
| 6c7f5277-174d-40df-8c23-0358066838f5 Spain | |
| 2f84582c-bf33-4616-a499-245f8c3b6aa7 Estonia | |
| a3aa936b-7b3d-4d43-9ea8-dc146e35d7b6 Germany | |
| 95f3f156-dd69-4ec1-9d14-78de866f6f31 Poland | |
| 26542a85-69e5-499d-9f6e-a7298e7cc2c7 Bulgaria | |
| 734ee33b-47e1-4293-8121-445151f1ab54 Norway | |
| 3a0f0a19-41a4-4704-b348-cccde816615d Hungary | |
| e2e606f8-e9a6-4509-8182-739ac12ee869 Portugal | |
| 4073126b-f7dd-402c-ab3a-904690724ad3 Sweden | |
| 1df00021-f9c8-4ea4-9d7b-028a4bdf68f9 Netherlands | |
| b48def77-79af-4ef1-b8d0-b792c88e1c95 Poland | |
| 52c692b5-378c-4f23-b6fb-a6326d43a568 Czech Republic | |
| 52841c46-0804-4d0f-a71a-115901554e52 Germany | |
| 854753fc-0f75-42b5-8743-d1cddb373a39 Denmark | |
| 1f22cb56-aa48-4536-ab30-ee74637cf8df Sweden | |
| d39daf4d-bf4d-4a7c-9b31-ac6079bd24c8 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2SPEFBD000A000000XX |
| EAN | 8015644747541 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644747541 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 34 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |