View larger
1SDA072888R1 ABB E2.2S 800 Ekip Hi-Touch LSI 4p WMP
1SDA072888R1
072888
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB air circuit breaker, part number 1SDA072888R1, serves as a primary protective device in heavy-duty electrical distribution systems, interrupting fault currents to safeguard downstream infrastructure. Units of this type are routinely deployed in industrial switchgear installations to manage high-amperage feeds reliably.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 56149e46-a526-4b67-a202-b1b41f896394 Italy
- Simplified SCIP: c9f064ee-d7b7-4410-87c8-55bc626ad426 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZBSPEFAJ200A000000XX
- EAN: 8015644767389
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 56149e46-a526-4b67-a202-b1b41f896394 Italy |
| Simplified SCIP | c9f064ee-d7b7-4410-87c8-55bc626ad426 Germany |
| 7caafd16-44e1-4198-ad67-0ea71da965da Poland | |
| cba8ab6f-1efe-4341-b9d4-268b0db9d670 Finland | |
| 696db809-b637-4ea6-9210-8dbd289276fc Germany | |
| a134b365-acbe-4e71-98bb-9c9e7ff26fe7 Denmark | |
| 9d16a165-6187-49f5-8d34-40e62291189e Sweden | |
| 90c57d02-b680-4f24-b96b-dae519ef7491 Germany | |
| 71bf9b89-2094-4d31-ac27-362599ba9f74 Germany | |
| aa083c7a-9606-423e-b1be-dc4c04cd9fa1 Spain | |
| 3ac28537-d3ec-46c9-83c7-076fada65b76 Poland | |
| cbca10d4-07d1-4d74-858d-2be9146626c4 Belgium | |
| e5d33829-62ba-4280-aff4-f1f018f537f3 Hungary | |
| 4bc69529-95c2-4b40-99f7-cf4509d46210 Bulgaria | |
| 089211bc-7713-40f2-b4e9-b4fdd45b1dca Sweden | |
| f19926ec-680c-4ad7-aac8-057cff1ad150 Norway | |
| 7c056124-fa1d-4375-9b57-02365e5ea897 Poland | |
| 9a344d02-8f27-4dfb-a79d-2d8376e86972 Germany | |
| 657889ed-f2bd-48f2-91e2-4f329058a3f9 Czech Republic | |
| 9b5f6caa-6ff8-4807-a509-eed5a9b514b4 Croatia | |
| 53782f20-8676-4250-b5f1-e10ad3cf6377 Belgium | |
| b5efef3b-2c3e-47ec-9e83-90e4dad79a89 Netherlands | |
| f8e119df-d695-4f15-a059-a5388c5f9bef France | |
| ebe2529f-6a81-458e-9be8-5f23eec1f7d2 France | |
| 90575958-fe5c-4c95-975d-51d6b920abe9 Greece | |
| 457d81c8-5224-40c0-b3d6-6041aede8176 Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBSPEFAJ200A000000XX |
| EAN | 8015644767389 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 407 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 55 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 60 kg |
| Package Level 1 EAN | 8015644767389 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0432 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 72 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |