View larger
1SDA072258R1 ABB E2.2S 800 Ekip Hi-Touch LSI 3p WMP
1SDA072258R1
072258
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB air circuit breaker, identified as 1SDA072258R1 ABB E2.2S 800 Ekip Hi-Touch LSI 3p WMP, delivers robust overcurrent protection and advanced trip unit intelligence for electrical distribution networks. Industrial operators utilize withdrawable breakers of this type within primary switchgear architectures to safeguard vital equipment.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: eb53c674-b8f8-43ef-8e8f-09dde75baae2 Italy
- Simplified SCIP: 233784f3-303a-46e6-b4ca-7dfeb592c109 Poland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2SPEFAJ200A000000XX
- EAN: 8015644761080
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | eb53c674-b8f8-43ef-8e8f-09dde75baae2 Italy |
| Simplified SCIP | 233784f3-303a-46e6-b4ca-7dfeb592c109 Poland |
| 90c4e3ea-0768-4613-ad65-af27ea803f86 Belgium | |
| 1fb568e0-81d0-4c58-8a2d-4d2ff132950f Croatia | |
| 48c83634-ced2-4ece-8788-1a7f63c39427 Finland | |
| d827a725-5508-4fbf-9b5d-617274436646 Germany | |
| 411ac2d4-54c3-4928-92ed-156d05e082aa Estonia | |
| 31fbf8ed-44e8-4ace-b774-4ac591928399 Bulgaria | |
| 8b835e5a-5821-4ff1-ab15-17ec356e13c1 Norway | |
| d494c8ba-c0e0-4760-8b2c-5cb98d5ec771 Denmark | |
| 3471cc35-27ff-41cf-9742-2b54933477ba Germany | |
| 38474cc9-218d-4940-bec0-ebd83d18f546 Czech Republic | |
| 03967ea9-767e-45ad-b718-18df775fc98b Portugal | |
| e0379821-9420-4dc6-a2d7-d62467c21a07 Poland | |
| bcb2be4a-9e5a-4bc9-9a3b-0e6ebc8f4993 France | |
| 76bd175f-b156-4957-9206-2c7ba51bfc3a Sweden | |
| ecbd1cb3-4725-4af4-9616-d438d633be1b Sweden | |
| 1760d099-47c4-4a3a-b740-53a775d6dd04 Poland | |
| 80a6a8a5-3734-4e71-bcc6-2b06f99729d7 Netherlands | |
| 59f93c6d-4dd7-4bc6-ba3b-6202eda57a7d Greece | |
| 9dd2d376-61d8-4103-ab0c-c92059aff8a5 Germany | |
| ab3e938b-7713-4727-bb77-712951d8fd70 Hungary | |
| 84e8616c-3c7a-42d4-8519-8e674d9ea3bf Spain | |
| c61f7fdf-4918-46a2-a1e6-ead4a3c160de France | |
| 75e47abd-744d-438a-83f6-94aa5420b1a6 Belgium | |
| 7402891e-e918-4632-a439-01b0f8791460 Germany | |
| 2c53aced-fbaf-447e-b80a-8c74fcd270e5 Germany | |
| c1fb72dc-4b4c-4eaf-8a1d-857976e2eae4 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2SPEFAJ200A000000XX |
| EAN | 8015644761080 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644761080 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0431 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 72 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |