View larger
1SDA072258R1
072258
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | eb53c674-b8f8-43ef-8e8f-09dde75baae2 Italy |
| Simplified SCIP | 233784f3-303a-46e6-b4ca-7dfeb592c109 Poland |
| 90c4e3ea-0768-4613-ad65-af27ea803f86 Belgium | |
| 1fb568e0-81d0-4c58-8a2d-4d2ff132950f Croatia | |
| 48c83634-ced2-4ece-8788-1a7f63c39427 Finland | |
| d827a725-5508-4fbf-9b5d-617274436646 Germany | |
| 411ac2d4-54c3-4928-92ed-156d05e082aa Estonia | |
| 31fbf8ed-44e8-4ace-b774-4ac591928399 Bulgaria | |
| 8b835e5a-5821-4ff1-ab15-17ec356e13c1 Norway | |
| d494c8ba-c0e0-4760-8b2c-5cb98d5ec771 Denmark | |
| 3471cc35-27ff-41cf-9742-2b54933477ba Germany | |
| 38474cc9-218d-4940-bec0-ebd83d18f546 Czech Republic | |
| 03967ea9-767e-45ad-b718-18df775fc98b Portugal | |
| e0379821-9420-4dc6-a2d7-d62467c21a07 Poland | |
| bcb2be4a-9e5a-4bc9-9a3b-0e6ebc8f4993 France | |
| 76bd175f-b156-4957-9206-2c7ba51bfc3a Sweden | |
| ecbd1cb3-4725-4af4-9616-d438d633be1b Sweden | |
| 1760d099-47c4-4a3a-b740-53a775d6dd04 Poland | |
| 80a6a8a5-3734-4e71-bcc6-2b06f99729d7 Netherlands | |
| 59f93c6d-4dd7-4bc6-ba3b-6202eda57a7d Greece | |
| 9dd2d376-61d8-4103-ab0c-c92059aff8a5 Germany | |
| ab3e938b-7713-4727-bb77-712951d8fd70 Hungary | |
| 84e8616c-3c7a-42d4-8519-8e674d9ea3bf Spain | |
| c61f7fdf-4918-46a2-a1e6-ead4a3c160de France | |
| 75e47abd-744d-438a-83f6-94aa5420b1a6 Belgium | |
| 7402891e-e918-4632-a439-01b0f8791460 Germany | |
| 2c53aced-fbaf-447e-b80a-8c74fcd270e5 Germany | |
| c1fb72dc-4b4c-4eaf-8a1d-857976e2eae4 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2SPEFAJ200A000000XX |
| EAN | 8015644761080 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644761080 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0431 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 72 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |