View larger
1SDA071706R1 ABB E2.2S 2500 Ekip Touch LSIG 4p F HR
1SDA071706R1
071706
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An 1SDA071706R1 ABB E2.2S 2500 Ekip Touch LSIG 4p F HR serves as a high-capacity air circuit breaker built to provide comprehensive protective tripping and phase isolation in heavy industrial electrical grids. These devices are frequently specified for primary switchgear assemblies to maintain system integrity against severe overloads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 59b043de-92aa-4d79-b705-e316dd72db8b Italy
- Simplified SCIP: 3a7bd26e-8a0c-401e-9590-aa942219383a Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZBSUELBF000A000000XX
- EAN: 8015644755560
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 59b043de-92aa-4d79-b705-e316dd72db8b Italy |
| Simplified SCIP | 3a7bd26e-8a0c-401e-9590-aa942219383a Germany |
| 490124b5-fa2d-40ef-ba7b-14bcbe70ed2d Poland | |
| 05c4dc27-1e7d-47e6-bbdc-36353fa1bd72 Czech Republic | |
| 7c088f80-c02e-4f4a-b5b5-0b6569080250 Poland | |
| 9617c2fe-99ed-4ce6-a15f-718dd1b346fc Portugal | |
| 223c051b-1ad0-4f71-ae0a-8f6fae34fe92 Sweden | |
| 5e9e97dc-176b-4f54-82b3-ebfd06130162 Poland | |
| d57fde10-b0e5-4ad0-9d12-47bb721cb449 Norway | |
| 0f914f96-46cd-42b5-8861-aa853a6833f1 Hungary | |
| ef38d03d-0625-4e30-b995-6fefe9eb4a0e Sweden | |
| 142a1aa0-a0cb-4f64-9595-a45ce82d562a Estonia | |
| b43b77f3-7c26-4c7a-931a-6ae9321f5514 Netherlands | |
| f3314b93-65cb-4cf2-abbf-781a5d0676a6 Finland | |
| 79e10286-6325-4f00-b19e-8c65c15a7115 France | |
| a7bf3ed2-55ff-476f-bd6f-474f1cd7d5b9 Greece | |
| 82e1e544-96de-441f-9d46-4b42a3fe1587 Denmark | |
| ea58df20-8e68-4e7a-971d-3dd63bf8e621 Germany | |
| dbb213fa-9a99-4f05-9adc-39dbbc4038a2 Germany | |
| 0a67407f-84cc-40b8-bd1e-61dbbe749032 Belgium | |
| 0d21afb0-4e14-4609-afd8-7ad27cc70c85 Bulgaria | |
| f3d5b044-3df3-4c5d-a32a-4fafbf94cd6c France | |
| 51eed759-b5e1-43ce-8914-1fef526584dd Croatia | |
| 10bdb1d3-8cf9-465d-a131-824c7692153d Germany | |
| 30dcc3d8-ac8d-4a8b-bb19-d8f07234c953 Germany | |
| 32b49cf7-dbeb-4fb6-a638-0dd91c94caa6 Belgium | |
| e7004a07-9621-474a-bf81-099e9eaadfc2 Spain | |
| 7eafc361-6322-47c2-ac59-5a1e4dc88732 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBSUELBF000A000000XX |
| EAN | 8015644755560 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644755560 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0123 |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 267 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |