View larger
1SDA070969R1 ABB E2.2S 1250 Ekip Hi-Touch LSIG 3p F HR
1SDA070969R1
070969
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA070969R1 E2.2S air circuit breaker is built to handle heavy electrical loads and fault currents in commercial and industrial power distribution systems. Equipped with sophisticated touch trip units, this device ensures precise system protection and monitoring. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 93951f71-79f6-4cd1-80e4-c7909f9baa54 Italy
- Simplified SCIP: 77c9f87f-2fbc-473a-81aa-8bbd001bd2df Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2SREHBK200A000000XX
- EAN: 8015644748197
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 93951f71-79f6-4cd1-80e4-c7909f9baa54 Italy |
| Simplified SCIP | 77c9f87f-2fbc-473a-81aa-8bbd001bd2df Germany |
| bffca4b8-cc43-4760-9490-599d85598d59 Poland | |
| e66feb15-45a7-402a-885b-567ad390a6e3 Poland | |
| 16400ca4-5e80-4420-982b-8573796a6059 Hungary | |
| d01d409d-835b-4eba-81f3-1a206a2f1b24 Belgium | |
| 59f22650-15c6-4cf3-81e8-936fb8c114dc Spain | |
| 2392a3fb-3f44-46f4-9dbe-35b3f18fd0a3 Czech Republic | |
| d856b782-40d9-4d5f-9eaf-6ac5d42fe19e Poland | |
| 283339fe-92aa-4860-af51-cda42672e306 Norway | |
| 6fd0a2c2-40a6-4c1b-8891-da5cc7f79bf9 Hungary | |
| f434cbad-8c1f-492e-9765-c8f8167927d4 Estonia | |
| 86d5c231-42f5-446b-a34e-43304d107673 Denmark | |
| 53abf30e-bf07-4085-8cce-5c8cd62100af Germany | |
| dbf528bf-9554-4f30-b26a-02c4a26f0b00 Germany | |
| 272adc79-6785-401e-80b5-e2b2e3cbcbcd Germany | |
| 0fc4f35f-d13c-4c03-8f09-abc9a3437745 Germany | |
| 6ac32107-d851-47e7-9702-8bef3e0e530d Sweden | |
| b7da3638-55c2-402e-8420-ae7abe843e93 Belgium | |
| 9396dbfd-071e-4f90-b7df-2f924996de4f Netherlands | |
| 80792894-4f83-4c20-9dab-294c74097336 France | |
| 0e3108de-20ee-4ddb-9c12-180961e99ce3 Greece | |
| c028809b-13c3-4445-9c69-71828cb7c52f Finland | |
| a1694668-4cc1-476e-99ef-3e2f5b40eebb Bulgaria | |
| 5e88e40e-524e-48d0-9f09-e7cf486a62a1 Croatia | |
| c50f5f90-efff-420c-bb42-c569d4703136 France | |
| 3d9c4630-bd46-4103-bfa8-16d8631b5e9f Portugal | |
| dcc2e542-6ea2-40ce-a663-fd493265c721 Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2SREHBK200A000000XX |
| EAN | 8015644748197 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644748197 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 83 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 85 kA |
| (230 V AC) 85 kA | |
| (380 V AC) 85 kA | |
| (400 V AC) 85 kA | |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 85 kA |
| (415 V AC) 85 kA | |
| (440 V AC) 85 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | S |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |