View larger
1SDA073047R1 ABB E2.2N 2500 Ekip G Touch LSIG 4p WMP
1SDA073047R1
073047
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This 1SDA073047R1 ABB E2.2N 2500 Ekip G Touch LSIG 4p WMP air circuit breaker acts as an essential protective switching apparatus designed to interrupt heavy fault currents and safeguard critical loads. Power distribution networks utilize these withdrawable units to maintain safety standards and facilitate scheduled maintenance.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: ff107143-1375-400d-b1ed-519a274ba3ef Italy
- Simplified SCIP: cb14f982-f875-4b5c-bfdd-97f7511274f0 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZBNUELAN200A000000XX
- EAN: 8015644768973
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | ff107143-1375-400d-b1ed-519a274ba3ef Italy |
| Simplified SCIP | cb14f982-f875-4b5c-bfdd-97f7511274f0 Germany |
| 6f30b537-7153-4f98-a953-bff08b0a6026 Poland | |
| d500eebf-6cba-44e7-8dee-94d130883158 Poland | |
| 0ff0466a-34a5-465b-9b6a-c3b4ea8c4f27 Sweden | |
| 153639c4-9fc5-4683-8c5a-0eac575eb38b Bulgaria | |
| 5f516a8e-bcbd-4768-92ec-72ecfe966845 Portugal | |
| 8f14f8b2-9903-4467-8ed1-8a2328f4802b France | |
| d259cdfb-fa57-4c0b-bb2d-f2ac1fb35dfd France | |
| 42f38e22-f1ca-43b7-9ff5-5a2bf28d0ec0 Croatia | |
| 3e849709-a297-4111-a67c-50a2f5c9686f Germany | |
| 2fbcb1ce-49a1-44f9-935b-901e79529757 Denmark | |
| fc169ae6-25fc-4162-92a4-021f1b2a495e Germany | |
| ae811754-a7a6-4f75-983a-fcfa42769b9a Germany | |
| 46bdea1b-56f8-43ba-b738-0081570ee37a Germany | |
| 64cc7c31-3a41-4db4-bfad-1b81676142cf Estonia | |
| d3e2853f-938d-48e2-9781-e2711b519f01 Netherlands | |
| 9352171d-69b7-4af3-88d0-7e2d8ef9468e Finland | |
| d9b6997c-4d3f-4b16-b43f-872b771f3ba4 Greece | |
| 827a455a-9906-4b39-80d9-07dac2f31edd Sweden | |
| c9a8bfeb-4f4a-4e4e-97c4-b198fb33c4dc Belgium | |
| c41670ba-fa49-4ff1-a1c7-2bcf614fadc9 Norway | |
| 41f43c0e-22fe-4931-b033-2909f275a149 Hungary | |
| 9c9caa9a-1b9f-4f90-97c5-8e4b8926d2aa Poland | |
| 691c276d-5d4b-44bb-ad7f-8f7993ab3f9b Czech Republic | |
| 6af6b88f-dfaf-4303-8d1f-620112068cff Spain | |
| e7c4620a-c472-4683-b15b-c1a20ba76c5c Belgium | |
| 3e50c1bd-74f4-496c-ab85-1d9023e39eb1 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBNUELAN200A000000XX |
| EAN | 8015644768973 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 407 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 55 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 60 kg |
| Package Level 1 EAN | 8015644768973 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 550 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 66 kA |
| (230 V AC) 66 kA | |
| (380 V AC) 66 kA | |
| (400 V AC) 66 kA | |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |