View larger
1SDA072420R1 ABB E2.2N 2500 Ekip G Hi-Touch LSIG 3p WMP
1SDA072420R1
072420
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Ensure reliable protection in primary electrical distribution systems with the Abb 1SDA072420R1 withdrawable circuit breaker. High-current switchgear units are standard in large industrial plants to control power flow and protect infrastructure from electrical faults.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 044180e5-6f76-40ce-9918-6fcec2ee89a4 Italy
- Simplified SCIP: 5a9417a4-d4dc-469e-b659-7d65faefd939 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2NUELAQ200A000000XX
- EAN: 8015644762704
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 044180e5-6f76-40ce-9918-6fcec2ee89a4 Italy |
| Simplified SCIP | 5a9417a4-d4dc-469e-b659-7d65faefd939 Germany |
| e14f9343-9ac8-4275-9a5e-5c4af95d4155 Hungary | |
| 4f26366d-98fc-4a18-b6f9-6f600f7d9bd7 Norway | |
| 054b2764-d829-4a48-9559-292c6d193906 Poland | |
| 2ca152d9-3b29-49d5-9b83-14852af653ac Finland | |
| abca4e6e-b487-419d-b09c-9a65a6147349 Greece | |
| 00e4e55f-3346-4158-8d55-76141b8317f3 Netherlands | |
| b3e0f49f-69a7-4b38-b129-64169b8f2364 Estonia | |
| 0b6d7c93-1f61-47b9-baf5-f65f3c87d784 Sweden | |
| 1d59c73a-b502-499b-b0e9-497186b3e411 Germany | |
| 816b1f7c-1ca4-4a9e-a732-b468d72681ca Belgium | |
| 13c17392-577f-42bc-8952-41a26a0c38c1 Croatia | |
| ce1dcd24-ed5b-4582-9b13-9dcc7520b25c Germany | |
| ff3e0f09-c775-48ee-926c-b0790617dcd8 Germany | |
| 274a21f1-1df9-4564-9b5c-128727a81482 Denmark | |
| cb8713e6-ac16-4f6d-a328-8ff8fd81ac3a Germany | |
| b550b15b-79f6-4dcd-a4c6-d23e984d9664 France | |
| c17e29a0-072d-4021-92a0-88aee7e5fcc4 Poland | |
| 3301dd44-94f8-444f-8572-514d3135e0de Poland | |
| b0a985e2-e65d-40f6-b722-817c7022db3e Czech Republic | |
| 3f699449-ad29-4fc4-a548-99e92b225067 Portugal | |
| 4002dfa4-467b-4a33-9963-6f8f3fb6030f Sweden | |
| 9ce8505a-53e6-47f5-a758-cf0f07ce489c Bulgaria | |
| 537b2d3a-6e6b-41d8-86fb-cdbf57c379af Spain | |
| 0d8e9d1d-0489-48c7-9d49-d585f2977781 France | |
| 58047b44-c364-4228-9b8e-d079d0461379 Belgium | |
| 5e6ef395-4736-4ebb-b408-2ba9ba92230a Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2NUELAQ200A000000XX |
| EAN | 8015644762704 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644762704 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 7000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 550 W |
| Rated Current (In) | 2500 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 66 kA |
| (230 V AC) 66 kA | |
| (380 V AC) 66 kA | |
| (400 V AC) 66 kA | |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 2500 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |