An ABB E2.2N 2000 Ekip Hi-Touch LSIG 4p F HR is a high-performance air circuit breaker designed to safeguard critical industrial facilities against overloads, ground faults, and short circuits. Modern electrical switchboards utilize protective breakers of this caliber to maintain system reliability and prevent costly downtime.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- Circular Design Principles Recyclability Rate: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- End of Life Instructions: 9AKK108468A2361
- Group Waste to Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Environmental Information: 9AKK108467A6707
- REACH Declaration: 9AKK108466A1424
- RoHS Status: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- SCIP: 3a4132ee-f344-4851-9548-60d9a92f1ad9 Italy (IT)
- Simplified SCIP: 408425be-9e7c-45c5-9ad9-1510cadb559e Germany (DE)
- Order Code US and Canada: ZBNTEKBK200A000000XX
- EAN: 8015644755195
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| Circular Value | |
| Circular Design Principles Recyclability Rate | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| End of Life Instructions | 9AKK108468A2361 |
| Group Waste to Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| Eco Transparency | |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Information | 9AKK108466A1424 |
| RoHS Status | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 3a4132ee-f344-4851-9548-60d9a92f1ad9 Italy (IT) |
| Simplified SCIP | 408425be-9e7c-45c5-9ad9-1510cadb559e Germany (DE) |
| f5394adc-c1c2-4168-b83d-f435fd250ea3 Hungary (HU) | |
| 2659ade6-8844-4518-a82b-74c5880dc26f Belgium (BE) | |
| b8849bda-54af-4f52-a960-e185333c125f Spain (ES) | |
| c0223ce4-7453-407a-84a3-12c4ce73ce1b Poland (PL) | |
| 18dc11ef-bd9a-479c-9892-e05b2993aa47 Hungary (HU) | |
| 363dd768-63a3-4cc3-9bec-7686a4440949 Norway (NO) | |
| 43a09334-3471-4ec0-b7d4-af8633b92508 Poland (PL) | |
| 7f3ddf22-94c7-4c9e-84ae-fe88809a5058 France (FR) | |
| ba249e6a-ad17-444b-ab2e-b20079d6d47b Bulgaria (BG) | |
| c6896f3c-4ae0-491d-914f-9c795986a4ed Croatia (HR) | |
| 8a7b7af1-86a9-4595-a59b-5863cd8e1a27 Germany (DE) | |
| 2c0d6231-8709-4c47-8e15-888966d110b6 Germany (DE) | |
| e5b816e9-76de-4b6e-bea1-712b54098aef Estonia (EE) | |
| cd7c5d32-4c71-413c-8cd6-420da74969f3 Belgium (BE) | |
| 5de17713-ad29-499b-89f0-2c9308b43640 Sweden (SE) | |
| bece4de8-0ef3-40b5-b02e-d1c4d33a943c Greece (GR) | |
| fbc19409-3d53-4fe6-8ad7-f6190c3cc4be France (FR) | |
| a899ded6-b8c5-4fcd-a996-0168f5b6bf50 Netherlands (NL) | |
| 8885989e-cf6b-44ee-a24f-9deb91e82f5d Finland (FI) | |
| 29e9ec7f-5b87-43e3-ac72-ebf9c3d071a7 Germany (DE) | |
| 4e90d549-e94d-4ba5-a5d9-8f161c937176 Germany (DE) | |
| 97e27791-3a36-43e3-8cef-8bf3d0f456e3 Denmark (DK) | |
| d9c38cb9-524a-4327-977a-059a931cca7d Poland (PL) | |
| c21a2260-5d5a-4ece-8b04-12a7b1a1887a Czech Republic (CZ) | |
| a60f1a69-59b0-48a6-8271-2c3db3db9d45 Portugal (PT) | |
| f2762db8-ac52-4d69-8612-a104d75caeeb Sweden (SE) | |
| Ordering | |
| Order Code US and Canada | ZBNTEKBK200A000000XX |
| EAN | 8015644755195 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644755195 |
| Additional Information | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4 |
| Power Loss | 212 W |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Current (In) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 66 kA |
| (230 V AC) 66 kA | |
| (380 V AC) 66 kA | |
| (400 V AC) 66 kA | |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Recommended Screw Driver | Main Circuit M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2.2 |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0123 |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| Classifications | |
| ETIM 7 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 8 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |