View larger
1SDA071039R1 ABB E2.2N 2000 Ekip Hi-Touch LSIG 3p F HR
1SDA071039R1
071039
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An air circuit breaker, represented by part number 1SDA071039R1 ABB E2.2N 2000 Ekip Hi-Touch LSIG 3p F HR, provides sophisticated fault protection and isolation for heavy industrial electrical distribution systems. It is typically deployed in primary switchgear setups to ensure selective tripping and system safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
- Simplified SCIP: a9dd8e8f-f9c1-4907-8cae-138ba62f3ed2 Poland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2NTEKBK200A000000XX
- EAN: 8015644748890
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy |
| Simplified SCIP | a9dd8e8f-f9c1-4907-8cae-138ba62f3ed2 Poland |
| aab5b06e-47f7-4aa7-8262-540667ab6d7b Sweden | |
| fe7bb089-613d-448f-a41a-5f28ef5af4ba France | |
| 9ce90478-75df-4efa-9fe0-c4e59bd91bfe Portugal | |
| 2a17ffdb-eb74-4ecf-8d94-454d1147c713 Sweden | |
| a865c6b2-1085-44d1-a0a5-3b56193d931e Finland | |
| a7b64e15-4e04-4ed8-9340-b0ebd52bc3f2 Belgium | |
| ec15cba4-4618-4eed-8af0-2352ed0ee334 Germany | |
| 74b271ee-e0cc-464e-a4ee-a6f72f90a2e4 France | |
| 9d5ec96f-3819-4d1c-acc1-d98e1aebe6de Germany | |
| cfaa6241-8301-48e1-be7d-e6d81412c080 Germany | |
| a007cb9c-0df6-4472-80ae-c6d51a3a804d Hungary | |
| 02969b09-cb5e-4f62-b936-f039eb7b26a7 Croatia | |
| 39532981-10fd-4cc2-a28a-41f9ee35be95 Greece | |
| 5d8cc241-9363-4750-bf36-9ed1a9ec609a Germany | |
| f9b5dec8-8443-4f8a-945d-0019e8bb4d2c Norway | |
| f052d9b0-d7dc-4e2c-b598-d03f5cfed086 Denmark | |
| 74b12d01-f2db-4074-ac8e-dc52b0025f4f Belgium | |
| 2d869ae8-b23c-4d64-97b5-3b9ac23d2029 Spain | |
| 5bd13e3e-3b94-4760-b1fb-d06528e7d3b2 Germany | |
| 08fcce69-fedc-4d2a-935e-67b68dffe56d Bulgaria | |
| 80a1a7ed-7cf7-4655-8f48-c6f7222552e3 Estonia | |
| 81076346-0875-4c35-a166-1c57cd196122 Poland | |
| 791cd72e-6f82-42e4-812a-96820dcdf856 Hungary | |
| f2dbbf0a-655e-4c60-91cf-e788d761d524 Czech Republic | |
| cad3abda-6c33-4a65-8c41-7a7279a6603d Netherlands | |
| 3cdfe5e4-6d10-4084-8e14-2fbe1fd30ccc Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2NTEKBK200A000000XX |
| EAN | 8015644748890 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644748890 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 212 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 66 kA |
| (230 V AC) 66 kA | |
| (380 V AC) 66 kA | |
| (400 V AC) 66 kA | |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |