View larger
1SDA072347R1 ABB E2.2N 1600 Ekip G Touch LSIG 3p WMP
1SDA072347R1
072347
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB part 1SDA072347R1 represents the E2.2N 1600 Ekip G Touch LSIG 3p WMP air circuit breaker, engineered for heavy-duty industrial power distribution and main switchboard protection. Devices in this category provide advanced circuit protection, fault isolation, and system monitoring in complex electrical infrastructures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 5b815497-7d50-4def-9f9b-dc4fedbf26d5 Italy
- Simplified SCIP: 1c7bd7be-1208-4851-a52c-1d688d2ba605 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2NSEJAN200A000000XX
- EAN: 8015644761974
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5b815497-7d50-4def-9f9b-dc4fedbf26d5 Italy |
| Simplified SCIP | 1c7bd7be-1208-4851-a52c-1d688d2ba605 Germany |
| 6e48eeb1-a266-48a4-9129-a1f7a70a8305 Spain | |
| 79b5a8ce-3893-4e2c-8107-b638b303e65f France | |
| 556454a9-3373-4457-a257-ea927f163784 Belgium | |
| 573fabbc-4626-4714-a70a-6058fe952488 Hungary | |
| 7fc7b86e-096f-4f39-97b3-16b58205e3ff Poland | |
| b6fdfc04-555f-489d-ac18-23b018a022f0 Norway | |
| 14fc9995-14d9-4ee5-bcef-ef5d4539c2fa Czech Republic | |
| d1c80746-e367-432b-ad59-f810e12cde62 Greece | |
| 5249a5a7-ce13-427a-84ee-7e97979ad1c6 Netherlands | |
| 49e91afb-dad8-490a-a0d2-b72ef2f8851c Finland | |
| d0d00bd6-57dd-45d7-b7a3-a1af45bf4319 Estonia | |
| d627b280-1dd8-4fa3-a69d-b11e429ab112 Sweden | |
| 8af2d5aa-efae-4543-90b0-7f5526abc5c1 Belgium | |
| 58846431-4236-47c5-b803-815155cb39fe Germany | |
| 1d1642c0-9399-471c-b872-1aba79e8d0f1 France | |
| f8032e52-6f01-485d-adf1-22a122efa613 Croatia | |
| c5a9e67d-806e-46ce-a419-248dd1da1b41 Germany | |
| cac5c8e8-7ccf-42ad-89c8-ac65a83eff05 Germany | |
| 2ef1d56d-85a2-4f34-97b3-42f466b1d10a Denmark | |
| e0392842-8fd3-4288-9ec8-396067db0924 Germany | |
| ce3c2ae6-2af2-42c3-b683-28dbfab1c48d Poland | |
| ac9c3a1a-765e-4b3d-804a-7f61eca32417 Poland | |
| dc7a98c3-b6ed-49ed-b460-71bf780483a7 Portugal | |
| d7922cec-c7b2-4b09-8857-468c8eaa12e2 Bulgaria | |
| d4c21523-4329-43a1-be79-ffeb24ac390c Sweden | |
| dc12bf7c-5e40-4ae1-a894-7007d0620aeb Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2NSEJAN200A000000XX |
| EAN | 8015644761974 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644761974 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 288 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 66 kA |
| (230 V AC) 66 kA | |
| (380 V AC) 66 kA | |
| (400 V AC) 66 kA | |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |