View larger
1SDA072350R1 ABB E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP
1SDA072350R1
072350
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA072350R1 E2.2N 1600 Ekip G Hi-Touch LSIG 3p WMP is a withdrawable air circuit breaker designed to protect critical power infrastructure and generator sets against complex electrical faults. Advanced electronic tripping units in these breakers ensure selective coordination and enhanced system reliability.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: ae7bebb0-71e1-4d4d-b496-8fafd1f9d6f5 Italy
- Simplified SCIP: 3ef2388b-d7ce-462c-92fc-417dc95e179e Sweden
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2NSEJAQ200A000000XX
- EAN: 8015644762001
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | ae7bebb0-71e1-4d4d-b496-8fafd1f9d6f5 Italy |
| Simplified SCIP | 3ef2388b-d7ce-462c-92fc-417dc95e179e Sweden |
| 853346ab-9815-4a36-b2d1-03496976c381 Germany | |
| d4ed424b-1423-46dd-a17a-6e9110670975 Germany | |
| 37bce78b-5fb4-41e8-8107-959410aad6c7 Germany | |
| 0b21eb76-4967-4914-9e0f-2326cd10ae1d Norway | |
| 320d7b51-d3b2-4c84-8f05-e4d507b9ab9c Poland | |
| 21d20545-985a-426d-ab26-011587e17a40 Spain | |
| 7218a69b-f568-405e-aa9f-ca9127d5bf8a Poland | |
| 9c805ec9-d327-4a8b-b9bb-07ea7cee709a Poland | |
| 8f5b8af5-7e50-41df-aa59-4cf72104ea89 Belgium | |
| 42852259-24bb-4d94-bfea-01cb828bd381 Germany | |
| ace22ded-3558-4273-83f5-09fd843c46e0 Finland | |
| b1229cbd-c08b-44e1-836f-caeb59d64c73 Germany | |
| 412cea7b-25f0-4a53-8827-5f1bce25e6dc Czech Republic | |
| bf5070bd-9fac-4d93-8b60-b1b2b720bb4f Belgium | |
| 2fdbc231-ea1c-49f6-96ef-07c44a639cfd Croatia | |
| 1aababf2-fa6e-450b-a5e5-6baa10682c7a Greece | |
| 13625463-ed2f-4775-8f11-d8d0e1e7c4f5 Bulgaria | |
| 4f31008c-bb6c-42d1-9de6-5bb2b45200f4 Portugal | |
| 1de85ead-73a6-4e3a-b9c8-4ae7e070df4c Denmark | |
| 37589718-bc95-4719-b2a1-dbba7a5e81a7 France | |
| 8688f7d4-40d8-4aed-9231-d1fad0d52263 Hungary | |
| c65b4653-8be1-45b3-9838-8c0f5da5c04c France | |
| e524083f-9b2c-4ad9-84d6-4b4297f76198 Netherlands | |
| 0344efd1-f33e-40af-b7db-0d21f36e111d Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2NSEJAQ200A000000XX |
| EAN | 8015644762001 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644762001 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 288 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 66 kA |
| (230 V AC) 66 kA | |
| (380 V AC) 66 kA | |
| (400 V AC) 66 kA | |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (660 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 66 kA |
| for 3 s 50 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 66 kA | |
| (525 V AC) 66 kA | |
| (690 V AC) 66 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |