View larger
1SDA070919R1
070919
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 92a19f2d-3c4a-4ec9-b5a7-11053b2748ab Italy |
| Simplified SCIP | b3e12a9a-b73d-4cbd-bb44-8c6903c42541 Germany |
| bd225601-5d99-4a29-b1cb-35fab596a2a8 France | |
| 4afd856d-d77e-4266-9321-019433a461c6 Hungary | |
| 8429bce6-f37c-41ae-9f40-c9d5eb61262b Sweden | |
| adc72d4a-5589-4841-b316-479f303d5e58 Poland | |
| 3272ce92-83df-45da-b561-3db79d8072a6 Spain | |
| 35c833cb-3d70-49d8-bec6-b08f7e7492ec Belgium | |
| fd6eac73-b7af-4db4-af1f-3ba94e50b690 Norway | |
| 2e9268d9-a173-4130-acb8-8d13ef442fc2 Poland | |
| f5b74abe-1287-4b88-a629-5fc5eb91bfa6 France | |
| 1fb1f45e-a587-4550-a087-749b8f97ee9f Germany | |
| 4341e68d-6f44-4f53-811a-72b226180c9b Finland | |
| e7abf9a6-d6db-4b6c-a1d5-c25bf4b28492 Germany | |
| 992d2cfe-d936-4bed-a536-8f530b231321 Denmark | |
| be5bde43-3f76-4ca9-8f30-6e5408c2f1b1 Germany | |
| bd9f1009-55da-4ea2-9668-0c1f12c3a2f2 Poland | |
| 7c3ee2c0-f21d-42a7-9a0e-561c997c8cd2 Belgium | |
| b41f9b5f-1561-4304-bb8d-2f32cddab4ae Czech Republic | |
| 251a6a3d-bf9c-41f7-8562-2f09c4b21d81 Croatia | |
| 9e6700e4-ef82-4cb2-8711-6a800f69826e Greece | |
| 1f6b7ebe-7e45-4cd4-9b82-1b9b4bd46d80 Bulgaria | |
| ccd47c0a-b61d-4c76-95f7-415b1f24b82c Portugal | |
| 2ea1ade8-9916-4f03-93a8-280ec86b53d7 Germany | |
| 6e810547-e4ed-4b89-ae80-108843f2ea6a Netherlands | |
| 83c00424-5343-4802-8378-2fab05da40f7 Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2HPEFBK200A000000XX |
| EAN | 8015644747695 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644747695 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 34 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |