View larger
1SDA071548R1 ABB E2.2H 800 Ekip Hi-Touch LSI 4p F HR
1SDA071548R1
071548
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SDA071548R1 ABB E2.2H 800 Ekip Hi-Touch LSI 4p F HR is a high-performance air circuit breaker engineered for reliable fault protection in commercial and industrial power grids. Such modular breakers provide precise monitoring and control capabilities within main switchgear assemblies. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 80828c5c-34ff-44cf-9751-d8c6bc4e6d95 Italy
- Simplified SCIP: 2dce2bdb-b9e8-4801-95fa-8045d2bd5cbc Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZBHPEFBJ200A000000XX
- EAN: 8015644753986
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 80828c5c-34ff-44cf-9751-d8c6bc4e6d95 Italy |
| Simplified SCIP | 2dce2bdb-b9e8-4801-95fa-8045d2bd5cbc Germany |
| 8978011c-4a9f-4227-b6a1-c5115fd27ba5 Sweden | |
| 6e8afd27-b512-47ae-ad0f-6f1e7f580cba Portugal | |
| 28663e31-06c2-4802-b74f-4da073d51350 Poland | |
| 0c6fc08e-da49-455b-95da-fc36cff195cc Poland | |
| 902c14ac-4113-4a60-bec7-a232632dbeb1 Czech Republic | |
| 9fe0c174-8f5d-46dc-bd01-c6e81a8c4fb6 Belgium | |
| dbed2743-afd1-4f14-afe5-b6c1d264dfa2 Finland | |
| f42a73c2-3cd7-4702-aa83-749d169f2f6b Greece | |
| edcc67d3-eb99-4a01-93e0-69621c8cb527 Netherlands | |
| c4d68e50-b7c0-4082-86b8-65b21226504a Estonia | |
| 3dcfb7fe-8293-451d-87a3-67ab9e804334 Sweden | |
| 19c01223-eb49-4df3-a619-7c57c0fce625 Bulgaria | |
| d084ed44-7f00-4aea-94f3-a052a4ad8dae France | |
| 2327f261-adfa-46bb-ba63-e4985515a65d Croatia | |
| 34dafd24-c09f-4b75-b962-8284a186aed0 Germany | |
| 227e02d5-15c6-4387-bea5-e3f2313daf83 Germany | |
| 2f9e0815-6f28-43c4-aae0-2d9e22c136f8 Germany | |
| 4c74e5c8-94fa-4975-9bac-ddab0159dc7c Germany | |
| 7976933a-e361-4118-8e0d-8850cd4a6af2 Denmark | |
| 1965c8f7-706b-4047-8f5c-f4a3b6c90e7a France | |
| 26a961e9-d85c-405e-9303-2fe89b95203a Norway | |
| 3618cdf6-c1cb-4cde-ae85-d2c1739c61f0 Poland | |
| 9a2caa11-5a1c-4091-afde-d33244cdca51 Hungary | |
| be3f130e-ca54-42b4-911a-c48f89387209 Hungary | |
| b6a09759-2e2a-4634-b6f8-327366cc6c4c Belgium | |
| 68940a30-b952-459c-a2d5-1bb66cf6fbcb Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBHPEFBJ200A000000XX |
| EAN | 8015644753986 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644753986 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0123 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 34 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |