View larger
1SDA071056R1 ABB E2.2H 2000 Ekip Touch LSIG 3p F HR
1SDA071056R1
071056
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E2.2H 2000 Ekip Touch LSIG 3p F HR is a high-capacity air circuit breaker employed in primary industrial switchboards to regulate electrical distribution and protect sensitive machinery. It provides precise electronic monitoring and fast fault clearance capabilities for complex power systems.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 45110bdd-378b-4366-8eb7-088bf524dd5b Italy
- Simplified SCIP: a4293ade-5bf4-41e4-9e9d-5b78e72b740c Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2HTEKBF000A000000XX
- EAN: 8015644749064
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 45110bdd-378b-4366-8eb7-088bf524dd5b Italy |
| Simplified SCIP | a4293ade-5bf4-41e4-9e9d-5b78e72b740c Germany |
| a90b6519-021d-4bb7-85e9-4394c080e673 Czech Republic | |
| edf290d9-5374-4884-89ad-2cfe17ecca95 Poland | |
| d31fa2ec-a4ba-45d4-a199-34282629f9c0 Poland | |
| b969ba04-01a9-4340-8e0b-1645cff35af2 Sweden | |
| b6bf38d3-a2a0-4014-a72f-9ccb4884d0b8 Portugal | |
| 1ed2e53b-b932-465a-876b-d300ad177f97 France | |
| 39b062a0-17ac-4488-9a66-baa4c6c1485c Norway | |
| f3b80939-81e2-4f33-8bc7-fd7ba9390a29 Poland | |
| 7f1ee56b-f739-4880-b857-29652d712275 Hungary | |
| aa6a0a86-6de0-41c0-94f5-0f1c93611ff0 Croatia | |
| 50030905-8c28-487c-ac46-d29ba31a828b Germany | |
| 3f48595b-b58a-48f2-a1e0-010ad47f9aad Germany | |
| e5a8555d-0719-4ec8-8b51-4bf6c19ffe21 Germany | |
| 614d5fb2-4e19-4c22-a50d-40925cea4a7a Germany | |
| c100e3cf-bd7e-4afb-b7ca-83065da15f4f Denmark | |
| 8412134d-0686-448a-9edd-d5827ff18c8f France | |
| 6e183057-4739-4ef0-8114-3dc373ee5ddc Bulgaria | |
| b1bfdfa8-88b8-41a8-8da9-a378cf8ff8b8 Belgium | |
| 23e7ae2c-e512-4264-b3af-1dbed32084bb Sweden | |
| 92d360c6-26af-4845-a10e-7efb5c8f7cf0 Netherlands | |
| a5db2f89-6116-450f-938a-ae0e42b92482 Finland | |
| df165dc5-5ad7-4eab-aa47-503103abfcbb Greece | |
| 43880553-fe17-451f-b96b-0816d9a55446 Estonia | |
| cb8c9b28-8269-40fe-9b33-ac39ac37bf42 Belgium | |
| 24036d84-0a24-4a3a-9608-5ca5d4497baa Spain | |
| 5e0ee98f-cb87-4b4a-b875-438e12cee649 Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2HTEKBF000A000000XX |
| EAN | 8015644749064 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644749064 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 212 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |