Request QuoteProduct Overview
Deployed in complex electrical switchboards, this ABB E2.2H 2000 Ekip Touch LI 4p WMP air circuit breaker manages large-scale power distribution while offering sophisticated trip characteristics to protect sensitive assets. Such withdrawable circuit breakers allow facilities to maintain high reliability and safely disconnect circuits during fault events.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy
- Simplified SCIP: b0f131c5-3b7b-44f5-a7ef-9b525fb1fd1e France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZBHTEKAD000A000000XX
- EAN: 8015644768843
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy |
| Simplified SCIP | b0f131c5-3b7b-44f5-a7ef-9b525fb1fd1e France |
| 649c5d8e-ae7e-41c4-8b6c-0973fa5d94fa Poland | |
| 03d2e9a0-743e-48d8-9da4-8768c4618594 Sweden | |
| a8a604f5-1159-4f31-ac9f-bd55746602fb Germany | |
| 8044a99f-312e-43eb-912a-cdedac08bb28 Bulgaria | |
| f9b7e887-0835-473a-a968-0daa23302026 Poland | |
| 366bb4f9-2bd4-49f3-a322-a9025c44fe4e Estonia | |
| bbc8d6d0-e1d9-48f5-8ff6-218a4d04e63d Hungary | |
| 8f427d20-f5a0-4203-82b7-30da9347a1f5 Denmark | |
| a70815d5-9515-4728-b85f-e0792b958c4c Hungary | |
| 5ddef1d2-8f05-4621-9bdc-44db754d7c17 Germany | |
| 5632f281-f41a-4250-98ec-bba3aa350b0f Croatia | |
| 7e540d07-433e-40ce-bad7-3e181f35f237 Greece | |
| dc058aa7-f896-4cc9-96c5-21e97a461035 Norway | |
| 47564c54-c21e-4731-8727-d0a98a3147c8 Belgium | |
| 73701582-eada-4ab5-a4a0-e2a601985ff4 Spain | |
| d71f9843-f444-441f-865e-727e5c312bc9 Germany | |
| 468c1067-647e-4b4a-a206-b82606bd2dae Germany | |
| e3db12a5-d2fa-44b2-8987-3d222da4a594 France | |
| 0f65428c-8b80-4b40-a80c-e516c8f65431 Germany | |
| e8932ad4-0823-4c13-b5de-9f86479d1712 Finland | |
| 82e87d0d-b7bc-4d8c-bb6c-6a0d1850e41f Belgium | |
| 7694bc76-df91-41cb-972c-6d71aa51ca75 Sweden | |
| 06bc6156-66f7-45ba-9769-3edb21c7a6bb Portugal | |
| e8c355a8-c6d3-460b-aaa7-2b7c904a93b6 Netherlands | |
| 3b43164e-e288-4ff3-9f8b-f9c6358067b5 Poland | |
| 99aba031-c3f0-4ba0-8a97-19a3175f7fb9 Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBHTEKAD000A000000XX |
| EAN | 8015644768843 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 407 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 55 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 60 kg |
| Package Level 1 EAN | 8015644768843 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0432 |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 450 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0102 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |