View larger
1SDA071016R1 ABB E2.2H 1600 Ekip Touch LSIG 3p F HR
1SDA071016R1
071016
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for heavy-duty power distribution infrastructure, the 1SDA071016R1 ABB E2.2H 1600 Ekip Touch LSIG 3p F HR acts as a main air circuit breaker managing high electrical loads in industrial switchgear. High-capacity facilities utilize these advanced units to provide precise trip curves, selectivity, and system protection across complex networks. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 9e5cbd43-8fb6-48e1-87cd-5dc8217a7ed5 Italy
- Simplified SCIP: 40f135ac-e0dc-455a-9d19-abe2c66f251d Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2HSEJBF000A000000XX
- EAN: 8015644748661
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 9e5cbd43-8fb6-48e1-87cd-5dc8217a7ed5 Italy |
| Simplified SCIP | 40f135ac-e0dc-455a-9d19-abe2c66f251d Germany |
| cbbf5660-8aec-4f9d-bd93-65424b50f482 Czech Republic | |
| 5eec0a7b-1b8a-4597-b0d2-f2f478a84612 Poland | |
| 3a621390-ded4-4f1c-841c-6e0288708bcc Poland | |
| a12322e9-7240-4516-b932-a048a617ecc2 Sweden | |
| 20d143b6-24c8-42de-80c2-9e119a9ec66e Portugal | |
| 96e160e5-08d1-40c6-bf96-287f4cafbf53 Germany | |
| 08d5b93e-6d01-4b99-af21-b3acb89fa4bc Germany | |
| 26f21a60-8d6d-45e1-9f33-36bf27343e50 Estonia | |
| ac293c58-794e-49c0-a775-f5cabffe41cc Sweden | |
| b2d4066f-3e86-44c0-9c78-7bb72a5fca8a Netherlands | |
| 62a6762e-af58-4cdc-9377-b109d5eac976 Finland | |
| 501536a2-042a-4cf6-8e86-9270988b32f1 France | |
| 66ec730b-6b23-4d90-8a49-c8c2e67b476d Germany | |
| b334c2f4-86b9-4b81-8fa5-07ef5e9d3dba Denmark | |
| a74f6877-11ff-4720-b29b-804dc13107c6 Germany | |
| 7ab8f0c3-a583-45a0-96b7-5f64e1e73fb9 Bulgaria | |
| 32f24a6a-f419-4096-afa2-2962fe43c208 Hungary | |
| cecbb30a-74df-4350-93a1-5251a8bdc2ba Poland | |
| 15f57b43-b133-48b3-b251-ea357c32226e Norway | |
| 5796e567-fb2a-414a-b8f9-62cf125d3722 Hungary | |
| 52512f79-1ac0-4d65-86f7-0b1528842155 Spain | |
| c9527207-a4d6-47f6-9f5e-a1d4c2336fd8 Belgium | |
| f3512ede-9632-4c68-b8e0-78a46ff7d740 France | |
| 05a9b3a8-84be-45bd-8415-3186be21907c Croatia | |
| 2a7c92c7-d771-49db-b7e9-9ee7bb2b00b6 Belgium | |
| 37889732-ab93-4f52-acf0-ce7977b39cab Greece | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2HSEJBF000A000000XX |
| EAN | 8015644748661 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644748661 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 136 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |