View larger
1SDA071571R1
071571
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 11dd7eff-49df-4082-8caa-c820871390ce China |
| Simplified SCIP | ada2d6da-cff4-43c9-98b6-7405e9dba775 Poland |
| b0c18d84-e1d9-41ea-8fda-fe2264e188ec Netherlands | |
| 207d1a52-a787-44ae-a6fa-9e1ef54493ad Czech Republic | |
| 4b3a7417-b2a4-4b60-8a35-078db7dab63a Poland | |
| d72a513d-0078-4145-802f-24290d1581b9 Sweden | |
| dd24e964-8698-453d-b3d9-365ecce976ea France | |
| c96106e6-3558-40f2-958d-65de32e80d44 Bulgaria | |
| 04adf39f-25a4-4009-977e-6ef6d2881e38 Germany | |
| 56afbe23-481a-440e-a7f2-4bde19570126 Hungary | |
| ba30a68e-eacb-41d5-8ae2-bf8f0859389a Estonia | |
| a7e4fc57-77df-42bd-b6fb-5d28d5b45ea4 Poland | |
| 4cbdfb06-7b84-422a-bbe4-31413dd2a5d7 Belgium | |
| b58348d9-e33c-4a09-8ca0-47bc8a1d23a9 Greece | |
| d4ada146-675a-48de-9629-ea8d1863fd3b Norway | |
| 8aad82d5-8873-4741-8cc9-ee14cb46dff2 Croatia | |
| 2d27b982-cc6e-4e11-be4c-5aa837ad61b1 Germany | |
| 23e368f6-c8a6-4a24-bc91-6c076ae488d0 Hungary | |
| 1bebb6bb-17db-4c87-a804-5537c4c557b1 Spain | |
| b4c0750a-2634-4884-92fc-a34a1d9660e7 Germany | |
| 2b30746a-f8dd-4c50-ae72-a54cb5aecf34 Germany | |
| fad9eb42-3a9b-4cac-9c8c-21b0e09676d9 France | |
| 23452c88-d449-46a4-b172-d13bf4193ab7 Germany | |
| c04d316a-802a-40f5-8cfa-9aa0ecfb11b1 Finland | |
| 0193822d-7fc0-42c8-978f-75f630c23543 Belgium | |
| 43747386-f1c4-4e0e-ac7a-fc841001d694 Denmark | |
| e0c3995d-40d7-4277-bd4a-455b96de9195 Portugal | |
| f67864f7-0531-46b3-a9d4-e2f0fbb9aa0e Sweden | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBHQEGBA000A000000XX |
| EAN | 8015644754211 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644754211 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0123 |
| Technical | |
| Connecting Capacity | 600 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 15000 cycle |
| Ue = 500 ... 690 V 15000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 53 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (380 V AC) 100 kA | |
| (400 V AC) 100 kA | |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (660 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 85 kA |
| for 3 s 66 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 100 kA |
| (415 V AC) 100 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 85 kA | |
| (690 V AC) 85 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |