View larger
1SDA071657R1 ABB E2.2B 2000 Ekip G Touch LSIG 4p F HR
1SDA071657R1
071657
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB air circuit breaker, part number 1SDA071657R1 E2.2B 2000 Ekip G Touch LSIG 4p F HR, provides advanced protection and monitoring for critical electrical installations. Industrial power distribution systems rely on such circuit breakers to ensure precise discrimination and safety.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 2afcf0d2-fe0b-4399-84d3-c52258ae8953 Italy
- Simplified SCIP: de9b7571-9f80-46f0-9740-5d5c52efd838 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZBBTEKBN200A000000XX
- EAN: 8015644755072
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 2afcf0d2-fe0b-4399-84d3-c52258ae8953 Italy |
| Simplified SCIP | de9b7571-9f80-46f0-9740-5d5c52efd838 Germany |
| 5555ae5c-b408-4926-9e54-9e2cd4047d10 Sweden | |
| 17db6ea0-1268-4775-9704-edb122f13bb8 Belgium | |
| 39db7ca0-1ce1-42f7-8487-28d6f3af66c4 Finland | |
| 799f8bb9-8b13-445c-b3f2-3ff4c41fee92 Estonia | |
| 38105997-aec5-4986-bebf-524356f54789 Portugal | |
| 2d125811-5210-40d7-b660-2ae6deb40177 Greece | |
| 7e16dda1-7d96-44e1-bedb-ffbc785f3fd2 Bulgaria | |
| 9f60a27c-4469-4603-bde5-d6a6fa5fe5d2 Denmark | |
| 2ea3d222-b8f2-4f70-90b1-21cd79a1f3b5 Germany | |
| 5a783855-5ada-43b3-9e09-04fa7e52b7a7 Poland | |
| 6e9aec41-ba18-43b4-8632-c1cd46e4529b Sweden | |
| b4836453-e86d-4b4c-a444-64916af045df Poland | |
| c61fcd66-dc79-4382-800d-d9f6161e3f37 Hungary | |
| 3c351e81-e1d3-440a-806c-87b4f1b62477 France | |
| f0b9dba9-0783-449e-a75d-034670f28b94 Norway | |
| 4da3149b-26fc-4da4-89cc-44e848a14065 Croatia | |
| b6972923-3313-47e3-85f7-40729c2e1e81 Netherlands | |
| ebb4fd5b-168a-4c4d-838a-08f4355a4ff8 Hungary | |
| b1ac7532-9efc-4f5d-940c-24ff7a37082c Germany | |
| 8b2dc316-a8e8-4319-91e3-5f5bfeb8f552 Poland | |
| 6d59b7f8-805c-46fd-9fd8-d8a601180c47 Germany | |
| c9af7281-07a4-4f77-80ee-3cc63188511e Germany | |
| 0058bc49-427a-4653-904a-19e7d46c2332 France | |
| c94ddfad-ae2f-41df-9dcf-97e3093a1b7e Spain | |
| cca160fe-b19e-4c29-a9da-6b386f80b391 Belgium | |
| 6374ac1a-fd98-4d29-93c5-9accb67e4503 Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZBBTEKBN200A000000XX |
| EAN | 8015644755072 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 58 kg |
| Package Level 1 EAN | 8015644755072 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Connecting Capacity | 1800 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 212 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 42 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip G Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |