View larger
1SDA070989R1 ABB E2.2B 1600 Ekip Hi-Touch LSIG 3p F HR
1SDA070989R1
070989
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E2.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 1SDA070989R1 air circuit breaker is built for heavy-duty electrical installations to manage and isolate high fault currents. These high-performance breakers protect massive infrastructure by cutting off power during overloads or short circuits.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108468A1902
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 79.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: eb7feea5-9751-458d-8ad2-2f63c31b0c39 Italy
- Simplified SCIP: a8793a2e-6a41-4858-918f-0a97b628917a Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z2BSEJBK200A000000XX
- EAN: 8015644748395
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108468A1902 |
| 9AKK108468A1909 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 79.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | eb7feea5-9751-458d-8ad2-2f63c31b0c39 Italy |
| Simplified SCIP | a8793a2e-6a41-4858-918f-0a97b628917a Germany |
| e1db96b3-5492-46c9-ae1c-9a32cfdecbcf Hungary | |
| 86597123-1e27-4c84-8e03-ea4803b54259 Belgium | |
| 4545fc80-6fc9-429f-8292-454476ea1cc0 Spain | |
| 69356f5b-b697-499d-8179-dbaf58a5188b Croatia | |
| 1a4cd8ef-39fe-4cc6-934f-25395fa79318 France | |
| f3683179-729b-4c85-8fe7-16ad0aeafc94 Bulgaria | |
| 75bd7e9a-af34-41a3-8327-92ba501082d7 Germany | |
| e86db012-e385-46ec-8fda-a38f38951a40 Germany | |
| 2a675041-a659-41a6-8d4f-85a4c5738a21 Estonia | |
| 538a17bf-00d9-485d-9034-2564ca9b8539 Germany | |
| eb2c05ab-6090-4100-bf53-5efc3b3939f2 Germany | |
| 12d7c73a-f48a-4346-bf9d-9212112e148e Denmark | |
| 4bd7cc76-55e5-4812-82fd-c72e322590b1 Sweden | |
| a835f983-de3a-4de4-b091-98e5d06e9b7b Netherlands | |
| d4e7bf9b-072a-451a-9a9e-8312884c8b7a Finland | |
| 6ebd6feb-64d9-499b-b4b5-ceaf27966be1 Greece | |
| baf10d4d-a262-4a55-8ca0-0556d99f9872 Belgium | |
| 3b144dd9-fb2b-45fb-b678-2d32f43298d3 Hungary | |
| dc61e717-fc94-453e-b8cf-83ce746e6d67 France | |
| 3d3e76b4-9125-4346-9f6b-c3ea98d9e37f Poland | |
| d7320a1a-1ca3-498c-b720-9776c12ae0f4 Norway | |
| 9d6603c2-a8ca-458b-9db4-b69b8b5b31e1 Poland | |
| 6861973e-4676-4928-93d7-47b27372581c Sweden | |
| 319e9960-06d7-4d9c-ad99-510cc417547d Czech Republic | |
| 7e099766-9d02-4cd6-aeb2-5e28f8277a7a Poland | |
| 5c2224b0-a1ea-46e8-9399-bd2a3a8e534a Portugal | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z2BSEJBK200A000000XX |
| EAN | 8015644748395 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 276 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 41 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 46 kg |
| Package Level 1 EAN | 8015644748395 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0083 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 12000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 136 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 42 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 42 kA |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (525 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Rear flat Horizontal |
| Terminal Type | Bolt |
| Tightening Torque | 70 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5902 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH001000R0100 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |