View larger
1SDA055625R1 ABB E1B 800 PR121/P-LSI In 800A 4p W MP
1SDA055625R1
055625
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E1B 800 air circuit breaker delivers advanced power control and high-current interruption capabilities for demanding electrical switchboards. These withdrawable circuit breakers serve as primary protective devices in heavy commercial and industrial power distribution architectures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: f5fa1c4f-6081-4c4c-9404-98e391a2bd11 Italy
- Simplified SCIP: d7d946fc-37c0-40ed-a179-5288f926f80e Germany
- Environmental Information: 9AKK10103A6076
- EAN: 8015644569655
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 414 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 54 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | f5fa1c4f-6081-4c4c-9404-98e391a2bd11 Italy |
| Simplified SCIP | d7d946fc-37c0-40ed-a179-5288f926f80e Germany |
| 74d471a5-0827-497d-9f5c-203778e5e0c6 Hungary | |
| 40ebdb13-9657-406f-ab49-851c40049f53 Germany | |
| b1080bac-9fe8-4d06-ae44-7f1650f3baf1 France | |
| 06e57866-adae-4665-aaf1-21884e847d0d Spain | |
| 1900fabb-bcf3-4285-b72a-7ac3e68db596 Belgium | |
| 0ed47bf7-177b-4b63-838d-ae678e430b5d Netherlands | |
| 3336e918-c7c9-4133-a085-cab118fe33e3 Poland | |
| 529433e4-3c25-47c5-b82b-02c82507feff Czech Republic | |
| cb3fd992-9ff6-4858-b204-e81f87628e53 Germany | |
| 2b6b792f-a1a4-45d4-9fea-29e249978e5a Croatia | |
| 5a809c4d-304e-493a-b58f-6ed8e62d91ba Estonia | |
| ff477798-3fd3-4d62-b96c-b8bcdb2ed006 Greece | |
| f181c2c6-3920-4a23-bff0-fff43fad31c0 Portugal | |
| f9570d62-0fdc-45d2-accf-0a6f58870d88 Hungary | |
| 4fa797bf-428c-42ae-aa54-7a18b6b0ffc4 Bulgaria | |
| 16473ff0-57c1-476e-82d2-b761a08f177e Poland | |
| 760618f8-89e0-41e5-aa0c-583eb9500a67 Sweden | |
| 6e1d3488-9a45-4229-86f3-c2427d36a89d Sweden | |
| 68eef3b0-58e6-48c1-9b97-c2912f148550 France | |
| 7b3791ab-0b15-41fb-86f6-6a53fadf085d Germany | |
| fea69faa-4366-47e0-b94d-34ced526d6a7 Poland | |
| 52e76f08-0e53-4d1d-85bb-95e7f5322416 Norway | |
| 23970081-5699-47ff-84d9-7ab8719447f6 Finland | |
| 6f99c34a-2eae-4446-a9ab-82f5c8f5ebe4 Belgium | |
| ef1a622e-a4c3-4e35-898e-c42b46a4cfed Denmark | |
| 946d600f-7a90-4c15-bbfe-54cfc082ae8d Germany | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644569655 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 414 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 54 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 615 mm |
| Package Level 1 Gross Weight | 67 kg |
| Package Level 1 EAN | 8015644569655 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 10000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 95 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 800 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0013 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |