View larger
1SDA055649R1 ABB E1B 1250 PR121/P-LSI In 1250A 3p W MP
1SDA055649R1
055649
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Service Breakers
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Built for robust power management, the 1SDA055649R1 ABB E1B 1250 PR121/P-LSI In 1250A 3p W MP acts as an air circuit breaker designed to handle large electrical currents and clear system faults safely. Such devices form the backbone of safe industrial switchgear architecture. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): Document availability on demand
- SCIP: dd9c9a29-0796-4862-864a-3c6ce35b7ac5 Italy
- Simplified SCIP: 5fe4670d-02cd-4db7-bebc-202cb7bb7777 Sweden
- Environmental Information: 9AKK10103A6076
- EAN: 8015644569891
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362090
- Product Net Width: 324 mm
- Product Net Height: 461 mm
- Product Net Depth / Length: 396.5 mm
- Product Net Weight: 44 kg
- Package Level 1 Units: 1 piece
- Package Level 1 Width: 515 mm
More info
▲| Material Compliance | |
|---|---|
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | Document availability on demand |
| SCIP | dd9c9a29-0796-4862-864a-3c6ce35b7ac5 Italy |
| Simplified SCIP | 5fe4670d-02cd-4db7-bebc-202cb7bb7777 Sweden |
| ff9947ea-a1dd-40c2-ac6d-9ada2a3e3f81 Poland | |
| 684401ee-587b-4a3a-afdf-0fff80cf8622 Spain | |
| 6e715c52-3911-48af-8c1b-446ba0824b58 Belgium | |
| 0c295e25-18c4-48a4-ac1f-179a3fa73a61 Germany | |
| 6116f134-94db-46ae-a666-968ee2096268 France | |
| fefbd4c1-9cde-4eae-b9b7-dd35814c8ba9 Poland | |
| 5f58a216-bfa0-47c7-8aa3-0c5c8c807e97 Norway | |
| 521657bb-04b3-4bc5-b6bb-e16d3ffbf434 Poland | |
| fbe18274-5209-4fb4-8d7b-fc9b9b9dbe18 Netherlands | |
| a26d79be-3cae-4c08-8dfc-662bfecb3350 Germany | |
| e216ce84-7e5b-45a1-b49b-778e554e276e Bulgaria | |
| a42ecfeb-0915-4599-b85e-b420b79f9b98 Portugal | |
| 017f15b8-3755-4431-b845-7d4d351ba25a Greece | |
| a0822963-8d9d-46f5-94b3-2a72f9def072 Croatia | |
| 4ed723b0-ef07-4413-9e79-1c6a4e0bdd13 Czech Republic | |
| 09ce275b-ab38-4d03-ac31-1b3210663647 Finland | |
| cb2b91ec-9189-4bab-a6c9-2ccdeae28f07 Belgium | |
| 1f080137-69c5-455a-9883-ce25e9de26fe Germany | |
| faaa059f-d955-425d-87ae-cb0d323d0cb0 Germany | |
| 066be6b6-9aef-4001-a535-8c74a401edf8 Denmark | |
| 28956f6d-192d-47b1-a01b-71c4d494b931 Germany | |
| 251f418f-fae9-4935-b7fc-6d692048f288 Sweden | |
| 51d4df99-0958-4019-9373-c8f44b95d274 France | |
| ad803a00-b972-4321-bdb8-e380fa602a2d Hungary | |
| Environmental | |
| Environmental Information | 9AKK10103A6076 |
| Ordering | |
| EAN | 8015644569891 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 324 mm |
| Product Net Height | 461 mm |
| Product Net Depth / Length | 396.5 mm |
| Product Net Weight | 44 kg |
| Container Information | |
| Package Level 1 Units | 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 600 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 55 kg |
| Package Level 1 EAN | 8015644569891 |
| Additional Information | |
| Product Main Type | SACE Emax |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 10000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 230 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 12 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Current (Ie) | 1250 A |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 42 kA |
| for 3 s 36 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 42 kA |
| (230 V AC) 42 kA | |
| (400 V AC) 42 kA | |
| (415 V AC) 42 kA | |
| (440 V AC) 42 kA | |
| (500 V AC) 42 kA | |
| (660 V AC) 42 kA | |
| (380 V AC) 42 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | PR121/P-LSI |
| Release Type | EL |
| Short-Circuit Performance Level | B |
| Standards | IEC |
| Sub-type | E1 |
| Terminal Connection Type | Withdrawable Circuit-Breakers |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200006D0209 |
| Declaration of Conformity - CE | 1SDL000165R0013 |
| Instructions and Manuals | 1SDH000460R0002 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| UNSPSC | 39120000 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |