View larger
1SDA071396R1 ABB E1.2N 800 Ekip Touch LSIG 4p F F
1SDA071396R1
071396
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An air circuit breaker, specifically the 1SDA071396R1 ABB E1.2N 800 Ekip Touch LSIG 4p F F, is deployed in heavy-duty commercial and industrial electrical architecture to safeguard high-capacity circuits. These robust protective devices provide reliable fault interruption, comprehensive trip unit monitoring, and secure isolation for complex power distribution grids. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 043c5e9b-a0b2-4d0c-ab30-8abba92d60b1 India
- Simplified SCIP: 56c7939a-2b3d-4d98-bc21-6bf0ea67e287 Spain
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANPEFBF000A000000XX
- EAN: 8015644752460
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 043c5e9b-a0b2-4d0c-ab30-8abba92d60b1 India |
| Simplified SCIP | 56c7939a-2b3d-4d98-bc21-6bf0ea67e287 Spain |
| 953c3745-2382-4696-8f8e-aa8eb10ccd10 Belgium | |
| a8d8550c-512c-481e-8d5b-bdc411356dd2 Croatia | |
| c91d6c5f-db11-4fdd-af9e-fbb199f0ea6f Hungary | |
| 38170aff-fd51-45b4-b9f1-de417cb3a604 Poland | |
| 3031f4cb-24c4-4a8d-bbcd-38e86e723f7f Hungary | |
| c9ec2238-4eb6-4424-a202-132bf8545719 Netherlands | |
| 4fae799b-6078-4cb7-bb90-016d72ac9322 France | |
| 6f23e069-a610-410d-b703-1455425ed31b Sweden | |
| 46502305-4b32-4f7f-85c9-24de68d61e37 Bulgaria | |
| f1221dbf-5108-41a0-9347-9f47be198130 France | |
| a7b4fb1c-e842-47d5-979d-dc9a17474644 Poland | |
| 700ece7b-993f-4d6d-9be6-4c528e30f072 Greece | |
| 26a7e73e-61a9-417e-9f33-f74a17077e1d Estonia | |
| b5527b34-115d-4f8b-8dc4-d944a4b29fa4 Portugal | |
| b7f869e7-cee8-46d0-b016-acdabc72332c Germany | |
| 78515a51-15bf-4065-a283-bc6238cc1be8 Germany | |
| 21794218-b054-466d-a60b-44acbd69c21d Sweden | |
| ef06c8fe-5830-4ab5-9687-8362b4a31014 Belgium | |
| 178e4032-7d09-47aa-8d3d-47e21f0963e3 Germany | |
| 39031698-706c-45ed-acd4-30f9166aff4d Finland | |
| 1356e764-2250-432c-a82a-d895c3417116 Czech Republic | |
| ba201e3e-fe1c-4574-ab5b-bc3232a2b41c Denmark | |
| c9060af4-863d-47f6-b19e-a6bdae557e41 Germany | |
| edcea31c-9271-4b73-93c1-f63a53b3066a Germany | |
| 952ce127-dc11-49f7-9ddb-1019936b7e70 Norway | |
| c38992ee-1d50-4b6d-bf07-94b145f484d9 Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANPEFBF000A000000XX |
| EAN | 8015644752460 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752460 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 50 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |