View larger
1SDA072741R1 ABB E1.2N 800 Ekip Dip LI 4p WMP
1SDA072741R1
072741
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An air circuit breaker, referenced by Abb part number 1SDA072741R1 ABB E1.2N 800 Ekip Dip LI 4p WMP, provides reliable protection and switching capabilities for primary electrical networks. It interrupts abnormal fault currents to prevent damage to downstream installations.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 96f9aca4-a452-4165-8bfa-3cb7d787d055 India
- Simplified SCIP: 3e4aaf46-8eba-42cf-990d-9487440d9fa6 Estonia
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANPEFAA000A000000XX
- EAN: 8015644765910
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 96f9aca4-a452-4165-8bfa-3cb7d787d055 India |
| Simplified SCIP | 3e4aaf46-8eba-42cf-990d-9487440d9fa6 Estonia |
| 39fc45c7-ca1d-4903-9cd3-b59135b92517 Greece | |
| 1453923b-03f7-4877-aaa7-e51d31274382 Sweden | |
| 23c7292e-766b-4c21-ba8c-0356a33294a5 Bulgaria | |
| da4d7663-a897-4ad0-bc41-1b62b56bca9f Poland | |
| cd3de073-3e04-4fb2-9b20-881e64d4b0ee Portugal | |
| d9799678-9ecf-41fa-a303-51a87204dda7 France | |
| de986f1a-5039-4c39-b8ff-490203c33d01 Sweden | |
| 7a3f7a54-a19a-4fe8-93d3-4c7e0d931acb Germany | |
| 7a45b483-e56f-418a-a68a-4cf3c026b1d6 Germany | |
| e6b8640e-67ed-471a-b644-d12895043e0f Germany | |
| d89516c6-b005-48fd-8a6b-89bcb17daa0a Finland | |
| f8920d39-1ac3-479a-9d2e-ae2a197d8b1e Belgium | |
| 1f5e61f7-b5d3-4e76-9f52-acd5eb27c168 Denmark | |
| b77b1da5-db3e-4acb-a9cd-be77a11b3e60 Germany | |
| 13944e2b-de6e-4208-a6c4-382c2229715b Germany | |
| 6510f218-2480-44b3-9c94-edfebe6330b0 Poland | |
| c98df397-1e33-4efd-b4bc-52c8c0f80549 Norway | |
| 7eaae8ea-1b2f-4709-806b-bdc21414ea4c Spain | |
| 53ddc9d4-a11b-46e2-b5fc-0fe29a6ef587 Belgium | |
| 934ab1d5-1754-4cef-a6b6-4ce297a0b0f5 Hungary | |
| 688f0734-039f-48f1-aaf9-a055b573864a Czech Republic | |
| 98d14f98-1bcb-4b36-b303-5ff4db1fa6c2 Croatia | |
| 72403cba-f9be-49ef-8261-73ed12ab3f72 Netherlands | |
| 68ce5e25-0d3f-4720-b660-77062aea7a16 Poland | |
| dba604b0-3f31-4ba8-b18d-72bc15cfa334 Hungary | |
| 2bc8355e-2b17-4196-ac91-f005becc9734 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANPEFAA000A000000XX |
| EAN | 8015644765910 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644765910 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 500 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 100 W |
| Rated Current (In) | 800 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 800 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |