View larger
Images are for illustrative purposes only. Please refer to data sheet for details
1SDA072075R1 ABB E1.2N 630 Ekip Touch LSI 3p WMP
1SDA072075R1
072075
ABB
1 Pcs.
E1.2N 630 Ekip Touch LSI 3p WMP
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A 1SDA072075R1 ABB E1.2N 630 Ekip Touch LSI 3p WMP withdrawable air circuit breaker provides modular system protection and precise electronic trip unit oversight in complex electrical distribution setups.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: a4531c46-d451-41e4-bafb-5fc41c0f1acf Italy
- Simplified SCIP: 4961b6e8-afec-4a5c-8ed7-6a9dc5ef7bcd Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1NNEEAE000A000000XX
- EAN: 8015644759254
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a4531c46-d451-41e4-bafb-5fc41c0f1acf Italy |
| Simplified SCIP | 4961b6e8-afec-4a5c-8ed7-6a9dc5ef7bcd Germany |
| 755b0427-eff0-4460-b2c6-a0e190ff9c29 Bulgaria | |
| 9f96fdce-84d2-4c38-b66f-58f6634f1647 Sweden | |
| a44fd514-d873-4b2c-a47d-d90b45239626 Portugal | |
| 61c3323a-d8e8-456d-b8bb-f55d721e8179 Poland | |
| 61873f48-f85d-4b5a-a6b7-8d99d9347b04 Poland | |
| e4210830-0835-420c-83ef-471f0b16c58f Czech Republic | |
| 9b5310f7-b954-4921-b9ce-ef830bc2db97 Spain | |
| ad42fd8e-763b-4ccc-85ce-cb5a0ae850c5 Belgium | |
| ea4a8ca5-bc8e-418a-82ad-370b125c07c7 Poland | |
| c182aeb1-d75c-45c9-8e45-0cd4919a3615 Norway | |
| 12ed0b6f-53a8-4e90-92c0-eae46bee7aaa Hungary | |
| 8487c914-ecab-4ce6-abac-627ecf57b28f Sweden | |
| b7045cda-e571-405e-8ec8-c498c1eebcdd Netherlands | |
| 1f7d95e5-25a7-431a-a317-cb8f08924c79 Estonia | |
| a4d8ca5e-9b33-4573-9fd7-bf48cf2897f5 Finland | |
| 3ecc0a4b-1d27-4671-9b44-60d0c463dc8d France | |
| 04fdb760-fa7c-4399-8769-4d638c88aec9 Greece | |
| 95127f28-831a-461c-b6e9-bd72d7b9263d Germany | |
| e5462bbc-5597-4783-9ee8-4ca106e9b6fa Germany | |
| cd36eb86-b8b6-4ad8-9022-1c8759c4a9b9 Croatia | |
| a059eb7c-9205-4ef3-a75c-ab89f359d248 Belgium | |
| fff07bf0-5a2c-4e91-9bbb-1b67adb112d8 Denmark | |
| 3f2c6a69-d021-40cf-bf97-b98c9245f91d Germany | |
| 7d48350f-7a35-4364-b446-30a282096488 Germany | |
| 418b83cc-684a-47df-b5a5-3e796cd98f59 France | |
| d828b577-0801-4a73-bd93-540bb407234c Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1NNEEAE000A000000XX |
| EAN | 8015644759254 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644759254 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 62 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |