Facilities rely on equipment like the 1SDA072702R1 ABB E1.2N 630 Ekip Dip LSI 4p WMP air circuit breaker to maintain safety and control in electrical distribution networks. These withdrawable breakers monitor current and interrupt faults to protect valuable downstream infrastructure.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 620cf2e1-129b-4ff7-99fc-060c14289786 Italy
- Simplified SCIP: a395b5eb-a9c5-43bf-96b7-a48374168aaf Finland
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANNEEAB000A000000XX
- EAN: 8015644765521
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 620cf2e1-129b-4ff7-99fc-060c14289786 Italy |
| Simplified SCIP | a395b5eb-a9c5-43bf-96b7-a48374168aaf Finland |
| 0c534691-a72f-4a23-bc59-044c75ce8aae Sweden | |
| 38fed5b8-1866-4846-88ed-1ff0a8e4a9be Germany | |
| 7a0c5d6c-b2b8-4eea-9414-e5bd3cb5db76 Denmark | |
| b28859f2-25fe-4d30-a6c0-7f116d60a2fe Bulgaria | |
| b4d12b6a-ce5d-4c38-9a7c-9dac038a9a79 Germany | |
| f3dacb43-6b4b-4f09-84ee-96e136cebcb2 Norway | |
| 1773b100-631d-4413-b4cb-1063874fbb04 Belgium | |
| 2222fe66-1c15-4c96-896c-8e72358d9b43 Belgium | |
| 6eea10a4-afea-404d-a56b-11073967b705 Germany | |
| 38fed5b8-1866-4846-88ed-1ff0a8e4a9be Germany | |
| c99bf6f5-f3d6-4163-a032-ca1cf6da332c Poland | |
| c7249468-398a-4648-849d-ffc37e2e68eb Poland | |
| 45903acc-c679-45a5-9e77-d6bc2709606c Hungary | |
| 7a0c5d6c-b2b8-4eea-9414-e5bd3cb5db76 Denmark | |
| 5c42d26b-9bbc-4ad5-bd3f-e311b4ba3321 Greece | |
| b4d12b6a-ce5d-4c38-9a7c-9dac038a9a79 Germany | |
| 6eea10a4-afea-404d-a56b-11073967b705 Germany | |
| 1773b100-631d-4413-b4cb-1063874fbb04 Belgium | |
| bf49b17e-d779-4f96-b171-87fea32d9f01 Croatia | |
| 5c42d26b-9bbc-4ad5-bd3f-e311b4ba3321 Greece | |
| c7249468-398a-4648-849d-ffc37e2e68eb Poland | |
| ef2f0046-7b38-456c-a740-f88b7a4032b1 Netherlands | |
| 779c0963-3721-4e10-8165-f56f8ba53fe5 Portugal | |
| aeb9a4ae-bbf6-4260-b817-d97611169a28 Poland | |
| 9080e34a-3d29-45ce-bbc9-f3a198682ad0 Germany | |
| d5f4d487-a08a-4cfa-91e1-5f4c0cb070ee Hungary | |
| 92447bf6-0dd9-48cb-9174-986b125a419d Germany | |
| 779c0963-3721-4e10-8165-f56f8ba53fe5 Portugal | |
| ef2f0046-7b38-456c-a740-f88b7a4032b1 Netherlands | |
| bf49b17e-d779-4f96-b171-87fea32d9f01 Croatia | |
| f79bd9ae-ec9e-43a4-84b7-3546260365bc Sweden | |
| a395b5eb-a9c5-43bf-96b7-a48374168aaf Finland | |
| 9ddff551-1a43-4c16-94db-bd0d7b797639 Czech Republic | |
| ec913f2d-7db1-4e91-9aab-5f92ddaecddc France | |
| f3dacb43-6b4b-4f09-84ee-96e136cebcb2 Norway | |
| 2222fe66-1c15-4c96-896c-8e72358d9b43 Belgium | |
| f5a38c15-b558-4308-a57d-83e585b09c49 Spain | |
| 45903acc-c679-45a5-9e77-d6bc2709606c Hungary | |
| 0c534691-a72f-4a23-bc59-044c75ce8aae Sweden | |
| ec913f2d-7db1-4e91-9aab-5f92ddaecddc France | |
| c99bf6f5-f3d6-4163-a032-ca1cf6da332c Poland | |
| 92447bf6-0dd9-48cb-9174-986b125a419d Germany | |
| 9080e34a-3d29-45ce-bbc9-f3a198682ad0 Germany | |
| 51392cc9-4769-483e-bd68-4d82f1571c64 France | |
| f79bd9ae-ec9e-43a4-84b7-3546260365bc Sweden | |
| 2a824d94-1381-469f-ac7c-c451df455bd7 Estonia | |
| f5a38c15-b558-4308-a57d-83e585b09c49 Spain | |
| aeb9a4ae-bbf6-4260-b817-d97611169a28 Poland | |
| 2a824d94-1381-469f-ac7c-c451df455bd7 Estonia | |
| 51392cc9-4769-483e-bd68-4d82f1571c64 France | |
| b28859f2-25fe-4d30-a6c0-7f116d60a2fe Bulgaria | |
| 9ddff551-1a43-4c16-94db-bd0d7b797639 Czech Republic | |
| d5f4d487-a08a-4cfa-91e1-5f4c0cb070ee Hungary | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANNEEAB000A000000XX |
| EAN | 8015644765521 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644765521 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 400 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 62 W |
| Rated Current (In) | 630 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 630 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |