View larger
1SDA072673R1 ABB E1.2N 250 Ekip Dip LSIG 4p WMP
1SDA072673R1
072673
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed for advanced electrical distribution management, the Abb 1SDA072673R1 ABB E1.2N 250 Ekip Dip LSIG 4p WMP provides precise monitoring and fault interruption in complex industrial grids. Air circuit breakers of this category serve as main or sub-main protective devices, ensuring selective coordination and safety across extensive low-voltage networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 261d3db4-8704-4d5b-832a-269f7bea313d Italy
- Simplified SCIP: 513695a4-20a9-46ec-af5d-7be4cbfef1bc France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANMECAC000A000000XX
- EAN: 8015644765231
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 261d3db4-8704-4d5b-832a-269f7bea313d Italy |
| Simplified SCIP | 513695a4-20a9-46ec-af5d-7be4cbfef1bc France |
| aa8c2116-566c-4a15-b5a0-482b0e294422 Germany | |
| 704a28f2-77bf-4f04-9dac-95f73827c1c2 Germany | |
| d26ad625-a799-4558-973c-589aaaa190fa Spain | |
| 49026641-dbca-4ead-95bf-ab8fd5b592b3 Hungary | |
| 48e10240-4fae-49a5-a3eb-0785ba2ce36c France | |
| ba8352b2-750e-40c2-bc79-410b86e0b8ba Belgium | |
| 790e661a-6016-4258-bb7b-6ea0ecff3f75 Croatia | |
| c53b27dd-7b1a-40f5-b28f-c243a0be8f76 Germany | |
| 57390c7d-ac93-4386-8db4-2f4255c9da05 Czech Republic | |
| bab51531-0d26-41f1-b23c-79f46d7f90e2 Poland | |
| 6813f689-76f8-4841-b0f2-567427a4ff18 Hungary | |
| 0fcb2885-9351-4e73-8735-3db7cc7bd5dc Netherlands | |
| 6be49062-244e-423a-9790-9925e4de9e38 Estonia | |
| 8c00adc9-ad4f-452e-96c4-c0033525ef36 Sweden | |
| 4e1e3542-4e4f-4df2-8d33-8f3aee652a1f Bulgaria | |
| cb4d4797-a9e2-4bb0-9166-f8cccadcf6bb Poland | |
| 31f2d5a1-9783-4faa-9c58-53d1f442eb99 Sweden | |
| b09f80c1-6835-43b4-83c8-d4af06b4a978 Greece | |
| 0c2d9d33-e52d-40d6-bc18-6dba2166f3bd Portugal | |
| 9d22b243-a3a4-4659-af65-e070b6449c50 Finland | |
| 48d50815-7b66-4312-93da-5f8a92bb29e4 Belgium | |
| 50e919dc-d0fa-42ae-9bd0-de341c29bbfa Denmark | |
| b4b0792a-10af-428a-bda3-795dc7ee0b4d Germany | |
| ae4b2d43-d7b7-49a0-af28-aa2797369358 Germany | |
| 98f157fc-59ad-4be2-85be-e75a479f8ac0 Norway | |
| c0329ef6-4e0e-4b6d-8e75-a4b467646e6c Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANMECAC000A000000XX |
| EAN | 8015644765231 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644765231 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 120 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 62 W |
| Rated Current (In) | 250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |