View larger
1SDA072673R1
072673
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 261d3db4-8704-4d5b-832a-269f7bea313d Italy |
| Simplified SCIP | 513695a4-20a9-46ec-af5d-7be4cbfef1bc France |
| aa8c2116-566c-4a15-b5a0-482b0e294422 Germany | |
| 704a28f2-77bf-4f04-9dac-95f73827c1c2 Germany | |
| d26ad625-a799-4558-973c-589aaaa190fa Spain | |
| 49026641-dbca-4ead-95bf-ab8fd5b592b3 Hungary | |
| 48e10240-4fae-49a5-a3eb-0785ba2ce36c France | |
| ba8352b2-750e-40c2-bc79-410b86e0b8ba Belgium | |
| 790e661a-6016-4258-bb7b-6ea0ecff3f75 Croatia | |
| c53b27dd-7b1a-40f5-b28f-c243a0be8f76 Germany | |
| 57390c7d-ac93-4386-8db4-2f4255c9da05 Czech Republic | |
| bab51531-0d26-41f1-b23c-79f46d7f90e2 Poland | |
| 6813f689-76f8-4841-b0f2-567427a4ff18 Hungary | |
| 0fcb2885-9351-4e73-8735-3db7cc7bd5dc Netherlands | |
| 6be49062-244e-423a-9790-9925e4de9e38 Estonia | |
| 8c00adc9-ad4f-452e-96c4-c0033525ef36 Sweden | |
| 4e1e3542-4e4f-4df2-8d33-8f3aee652a1f Bulgaria | |
| cb4d4797-a9e2-4bb0-9166-f8cccadcf6bb Poland | |
| 31f2d5a1-9783-4faa-9c58-53d1f442eb99 Sweden | |
| b09f80c1-6835-43b4-83c8-d4af06b4a978 Greece | |
| 0c2d9d33-e52d-40d6-bc18-6dba2166f3bd Portugal | |
| 9d22b243-a3a4-4659-af65-e070b6449c50 Finland | |
| 48d50815-7b66-4312-93da-5f8a92bb29e4 Belgium | |
| 50e919dc-d0fa-42ae-9bd0-de341c29bbfa Denmark | |
| b4b0792a-10af-428a-bda3-795dc7ee0b4d Germany | |
| ae4b2d43-d7b7-49a0-af28-aa2797369358 Germany | |
| 98f157fc-59ad-4be2-85be-e75a479f8ac0 Norway | |
| c0329ef6-4e0e-4b6d-8e75-a4b467646e6c Poland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANMECAC000A000000XX |
| EAN | 8015644765231 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644765231 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Connecting Capacity | 120 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 62 W |
| Rated Current (In) | 250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 250 A |
| Rated voltage (EF003977) | 690 V |
| Rated short-circuit breaking capacity Icu at 400 V, 50 Hz (EF007048) | 66 kA |
| Overload release current setting (EF002336) | 100.0 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 150.0 A |
| Adjustment range undelayed short-circuit release (EF007131) | 375.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 4 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |