View larger
1SDA072235R1 ABB E1.2N 1600 Ekip Touch LSI 3p WMP
1SDA072235R1
072235
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SDA072235R1 E1.2N 1600 Ekip Touch LSI 3p WMP is an advanced air circuit breaker engineered to protect critical electrical distribution infrastructure from overloads and short circuits. These draw-out circuit breakers allow for safe maintenance and reliable trip coordination in commercial and industrial switchgear. Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: c9e8d2f2-171e-4cf9-a48c-41ced1824f91 Italy
- Simplified SCIP: fcc97ad9-6157-44dc-b7ba-58a2ded89431 Germany
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1NSEJAE000A000000XX
- EAN: 8015644760854
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | c9e8d2f2-171e-4cf9-a48c-41ced1824f91 Italy |
| Simplified SCIP | fcc97ad9-6157-44dc-b7ba-58a2ded89431 Germany |
| 9587b36b-5762-4cad-a3c6-17e59c29a16d Sweden | |
| 8d07be4a-9943-4830-8bd7-e5184b9c9424 Poland | |
| 7081f648-f888-40a4-ad1b-d920fdb7d90d Germany | |
| e57ea888-98c1-43bc-8942-049fa7d0fbf6 Germany | |
| acb5ef65-89ba-4848-b35d-8f2c1012e534 Bulgaria | |
| f9491114-29f3-4d25-922d-fa9a7cd4aa9d Poland | |
| 28172059-0df6-476c-93e1-93cd518e44bb Portugal | |
| ddf5d835-d1d7-4365-acc2-6ab2ed13fff6 Sweden | |
| 6932bf70-bb19-4290-aa76-333caa0c0e8e Hungary | |
| e8cb9571-113a-489b-b9d0-e97b30768cc1 Estonia | |
| b83d815d-9462-4960-9b34-ae8534ee44f9 Greece | |
| 0c3258a0-7196-48c2-a666-726d77688f87 Denmark | |
| 01f96c33-359d-491c-baf6-4e63440ee2f4 Poland | |
| fe285f23-7f44-41b2-9506-fee33ce22725 Norway | |
| 9e4a0a52-a0cb-409c-af6c-e7020d75027d Germany | |
| 3a79e436-9c22-4c44-80ce-da4af3422035 Finland | |
| 11de18f9-47b2-4271-af7e-efb7aef63552 France | |
| 7cd34288-87c6-4674-be96-125f6cf31c8a Croatia | |
| 0e695a2c-84e0-40ba-a007-15e66e9386d9 Spain | |
| ecfd2284-2f8b-4c37-956a-caf344d27b8e Netherlands | |
| fc9a616b-9fa3-4c64-826d-9da5fb455a16 Belgium | |
| 2050f275-759d-4054-85b7-77c128ab2b91 France | |
| 2ac4c111-044e-4063-81ff-9f9c608394ea Hungary | |
| b5eb7c1d-d2e6-4f81-9d20-391e14771777 Germany | |
| 78ac3a15-9b87-4ec5-9db7-e8955c3a38a9 Czech Republic | |
| e5c30369-7d8c-4d7f-bcaa-289d0d875662 Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1NSEJAE000A000000XX |
| EAN | 8015644760854 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760854 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 400 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |