View larger
1SDA070885R1 ABB E1.2N 1600 Ekip Touch LSI 3p F F
1SDA070885R1
070885
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a core protective device in major electrical distribution panels, the 1SDA070885R1 ABB E1.2N 1600 Ekip Touch LSI 3p F F interrupts abnormal fault currents to protect heavy industrial infrastructure. These circuit breakers provide reliable fault isolation and advanced circuit monitoring in commercial and utility power systems. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 7600c1d0-0011-4552-bd51-7fc9177b9b3f Italy
- Simplified SCIP: c6f41e14-c441-4611-8fec-5fc070f69ae8 Sweden
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1NSEJBE000A000000XX
- EAN: 8015644747350
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 7600c1d0-0011-4552-bd51-7fc9177b9b3f Italy |
| Simplified SCIP | c6f41e14-c441-4611-8fec-5fc070f69ae8 Sweden |
| 626e3e5b-87ce-4a47-84ea-34776cc4c3b5 France | |
| 3e33fc16-9f9d-4e6d-abe0-1e1d6576593a Poland | |
| ef11d481-aaeb-495c-8234-1188d676d99d Germany | |
| 59d42db2-54a4-463d-a9ec-1d606d819aad Sweden | |
| 06d07bf4-f5ba-43f3-8e42-20a13ebaccec Germany | |
| fa3dbf56-1433-47e7-b9fb-1091765d5785 France | |
| 25aec7e7-e539-4438-a833-fda340bec116 Estonia | |
| 77544aad-4a7f-42bc-9ad4-89ba83236e72 Spain | |
| 3762abb8-3691-4c5e-846b-62407b9b6989 Poland | |
| 25aec7e7-e539-4438-a833-fda340bec116 Estonia | |
| fa3dbf56-1433-47e7-b9fb-1091765d5785 France | |
| 77544aad-4a7f-42bc-9ad4-89ba83236e72 Spain | |
| 622523dd-879e-42fb-807e-100193976ef8 Belgium | |
| dca94855-dbbe-4573-b381-348bfd1fefcf Hungary | |
| 059bc3fb-0c0d-47b4-a601-baf3db88a309 Bulgaria | |
| 9b15b4dc-329c-470e-a692-8a11486889ba Norway | |
| 8cf67482-0a32-47b6-be74-031c4292a4d5 Germany | |
| c5bd6e53-b46b-44ec-9115-24e2af16d858 Denmark | |
| 2d19e74e-a3af-4377-960e-40f5224b3838 Germany | |
| c6f41e14-c441-4611-8fec-5fc070f69ae8 Sweden | |
| 7cf06ee4-9a87-4498-87dc-0a49ec4a9355 Belgium | |
| 8cf67482-0a32-47b6-be74-031c4292a4d5 Germany | |
| 6080fc1a-40ea-4d7f-89a2-3e0e628b0d06 Finland | |
| 642fae34-4e73-426f-8a71-90126af3fa98 Croatia | |
| 22d104ea-b057-4682-815f-13bae135cb0c Germany | |
| 3e33fc16-9f9d-4e6d-abe0-1e1d6576593a Poland | |
| 13170f20-aade-431a-983b-4a6133b846f0 Poland | |
| 59d42db2-54a4-463d-a9ec-1d606d819aad Sweden | |
| 42fa8e15-9be6-447e-a7e1-a7c3aad50e77 Hungary | |
| ef11d481-aaeb-495c-8234-1188d676d99d Germany | |
| 06d07bf4-f5ba-43f3-8e42-20a13ebaccec Germany | |
| e40992e8-a576-42d5-b821-4384701da300 Czech Republic | |
| 059bc3fb-0c0d-47b4-a601-baf3db88a309 Bulgaria | |
| 42fa8e15-9be6-447e-a7e1-a7c3aad50e77 Hungary | |
| 9b15b4dc-329c-470e-a692-8a11486889ba Norway | |
| 2d19e74e-a3af-4377-960e-40f5224b3838 Germany | |
| 22d104ea-b057-4682-815f-13bae135cb0c Germany | |
| dca94855-dbbe-4573-b381-348bfd1fefcf Hungary | |
| c5bd6e53-b46b-44ec-9115-24e2af16d858 Denmark | |
| 535d6a3d-c609-433a-8d5b-68055a62e4c4 Greece | |
| 626e3e5b-87ce-4a47-84ea-34776cc4c3b5 France | |
| 642fae34-4e73-426f-8a71-90126af3fa98 Croatia | |
| 9f6ebf27-f90c-4477-9ead-068ab42d6819 Netherlands | |
| e40992e8-a576-42d5-b821-4384701da300 Czech Republic | |
| 6080fc1a-40ea-4d7f-89a2-3e0e628b0d06 Finland | |
| cbad1b4d-e155-4ee8-9a5d-d57402a3d51f Portugal | |
| 535d6a3d-c609-433a-8d5b-68055a62e4c4 Greece | |
| 622523dd-879e-42fb-807e-100193976ef8 Belgium | |
| 7cf06ee4-9a87-4498-87dc-0a49ec4a9355 Belgium | |
| cbad1b4d-e155-4ee8-9a5d-d57402a3d51f Portugal | |
| 3762abb8-3691-4c5e-846b-62407b9b6989 Poland | |
| 13170f20-aade-431a-983b-4a6133b846f0 Poland | |
| 9f6ebf27-f90c-4477-9ead-068ab42d6819 Netherlands | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1NSEJBE000A000000XX |
| EAN | 8015644747350 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 14 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 8015644747350 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0001 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | Main Circuit M10 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |