Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Designed as an air circuit breaker, the 1SDA071519R1 ABB E1.2N 1600 Ekip Hi-Touch LSIG 4p F F from Abb manages heavy electrical loads and safeguards primary power distribution networks. These units are deployed in industrial plants and switchboards to interrupt high fault currents and provide precise trip coordination. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 66362b38-a204-4083-b04a-eb5b357497e0 Italy
- Simplified SCIP: 986b1368-3be6-4f43-af5d-bbf2a9da8501 Belgium
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANSEJBK200A000000XX
- EAN: 8015644753696
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 66362b38-a204-4083-b04a-eb5b357497e0 Italy |
| Simplified SCIP | 986b1368-3be6-4f43-af5d-bbf2a9da8501 Belgium |
| 8c09d60a-abc9-45c3-9992-7fde43fd16b3 Spain | |
| dc6c8632-c8c3-4f63-bce6-5434d88c6a2c Germany | |
| c8c5e97e-3365-4fba-8faa-eac6359a51e1 Hungary | |
| b236b713-6e47-4926-8982-0633dd6bcc65 Germany | |
| 43bcf180-ed10-4999-a2a2-d7dbb5fac635 France | |
| 656d590d-2d69-4598-b330-7dfe6128a258 Hungary | |
| c36b5285-9966-4c9f-98f5-5f160b509190 Estonia | |
| 8f17c535-ed5f-4d93-a99b-13c900636152 Bulgaria | |
| be73e454-2bfc-4d61-b7af-60bf2204bf6b Sweden | |
| e56e4d00-f1f3-4525-9b25-aa6971137883 Portugal | |
| e6729b94-11c2-4ef2-b031-00a0413af0e3 Greece | |
| 4a2b4e71-2041-48a1-bab9-b305a47ba1c9 Poland | |
| 1cbd1dbe-28e0-49da-b29e-437b9c75bd03 Czech Republic | |
| 2b16ef7c-62cc-424f-9db1-eb41d34ed615 Poland | |
| 8d0ec000-8e4c-43de-b1e8-73199d9b9ce3 Netherlands | |
| 52af1868-814a-40fe-80a8-d5a297717071 Croatia | |
| 344931b1-9cb7-45d0-b31a-0719e39c7580 Germany | |
| 07682f91-d679-4b1f-badb-42b346549c4b Sweden | |
| 558a272e-7def-4474-8710-5f8235c7c4f8 France | |
| a6390b4a-c9c5-4025-bff1-a461c35e88d1 Denmark | |
| 98f828df-a7fd-4390-a168-fcd054f46fe9 Germany | |
| c99e6ecc-31bb-4493-ba6b-1118ce68c4b5 Poland | |
| ffffa82a-f1e5-43fd-b04a-23a6566ce2f3 Germany | |
| 95023f90-e6e7-4c53-9065-9c7354f70ed7 Belgium | |
| 53c54a3c-e5dc-4e03-99a2-948fd84165fd Norway | |
| 89c8468d-0df6-40b5-8af5-a4da69376f03 Finland | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANSEJBK200A000000XX |
| EAN | 8015644753696 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753696 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1200 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 3000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 201 W |
| Rated Current (In) | 1600 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1600 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |