View larger
1SDA072194R1 ABB E1.2N 1250 Ekip Touch LI 3p WMP
1SDA072194R1
072194
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The ABB E1.2N 1250 Ekip Touch LI 3p WMP serves as a withdrawable air circuit breaker used to control and protect high-amperage electrical circuits. Switchgear assemblies depend on withdrawable breakers to ensure safe servicing procedures and reliable power distribution.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 90829932-f9fa-479d-9fae-907b3d0af3f5 Italy
- Simplified SCIP: 65bb56df-8585-425c-ab0f-c3799594bf71 Norway
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: Z1NREHAD000A000000XX
- EAN: 8015644760441
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 90829932-f9fa-479d-9fae-907b3d0af3f5 Italy |
| Simplified SCIP | 65bb56df-8585-425c-ab0f-c3799594bf71 Norway |
| b75dd9e3-3820-406e-afa4-cb3f706e8c3c Germany | |
| 51020fcc-40fd-44fe-9813-8f4c300ccbd8 Germany | |
| ba69be87-6115-4efd-90e6-212be4bbc1d3 Germany | |
| 8aea2ba7-9c24-4438-84ab-1c4534d4641d Hungary | |
| 83b69791-6d88-4f15-b8b7-64772f3ab775 Germany | |
| 05e45509-1ed3-43db-bbb6-4e113b959382 Sweden | |
| 98473819-49a5-4331-bba3-6a26c1b74ce8 Croatia | |
| a4b97dfa-9052-456d-842e-700815428860 Portugal | |
| 667b83a2-0651-406f-bcec-4be0e6852273 Poland | |
| 25cfcdb3-cb19-4615-b466-217bcbebcd7e Poland | |
| 6d892923-cff5-40b8-97fc-cbf1ae37e12e Netherlands | |
| 51020fcc-40fd-44fe-9813-8f4c300ccbd8 Germany | |
| a4b97dfa-9052-456d-842e-700815428860 Portugal | |
| f95a72df-858c-4f41-a002-af402ac9d79b Czech Republic | |
| 15b64bf6-8bfc-4e44-b7e0-5558f34cfbb2 France | |
| b8bece7b-584b-4c79-b1b7-f98b98046591 Sweden | |
| d50def89-821b-4a30-ab6e-d19aaea15d35 Finland | |
| b75dd9e3-3820-406e-afa4-cb3f706e8c3c Germany | |
| e94a8fd6-a2f5-44cc-88f8-bfe2b3be3727 Poland | |
| 25cfcdb3-cb19-4615-b466-217bcbebcd7e Poland | |
| 326cd43f-5f0e-4cf2-a843-6b21e4c97d01 Hungary | |
| d50def89-821b-4a30-ab6e-d19aaea15d35 Finland | |
| 1f6a0bde-7782-457b-930c-cc1f7167390b Denmark | |
| 257626e7-a8c7-42c5-af35-be95d4493c32 Greece | |
| 957e1ce7-d460-4107-a1e8-dd43cbaab86a Belgium | |
| 98473819-49a5-4331-bba3-6a26c1b74ce8 Croatia | |
| fbb74cf5-d315-4961-bfa0-427b894f963f Germany | |
| b8bece7b-584b-4c79-b1b7-f98b98046591 Sweden | |
| 05e45509-1ed3-43db-bbb6-4e113b959382 Sweden | |
| 15b64bf6-8bfc-4e44-b7e0-5558f34cfbb2 France | |
| e94a8fd6-a2f5-44cc-88f8-bfe2b3be3727 Poland | |
| 83b69791-6d88-4f15-b8b7-64772f3ab775 Germany | |
| 717bc21a-f2f3-4264-b7c5-c7ed028793dc Estonia | |
| 667b83a2-0651-406f-bcec-4be0e6852273 Poland | |
| 8aea2ba7-9c24-4438-84ab-1c4534d4641d Hungary | |
| f95a72df-858c-4f41-a002-af402ac9d79b Czech Republic | |
| fdd5319c-4db6-414b-906a-c19344887512 Bulgaria | |
| ba0c2b28-6be1-4a44-8eb9-0e643281bd05 Spain | |
| 717bc21a-f2f3-4264-b7c5-c7ed028793dc Estonia | |
| 257626e7-a8c7-42c5-af35-be95d4493c32 Greece | |
| 8dc61bc0-bdf6-4075-86a7-a7dc559a56aa France | |
| 6d892923-cff5-40b8-97fc-cbf1ae37e12e Netherlands | |
| 326cd43f-5f0e-4cf2-a843-6b21e4c97d01 Hungary | |
| 8dc61bc0-bdf6-4075-86a7-a7dc559a56aa France | |
| ba69be87-6115-4efd-90e6-212be4bbc1d3 Germany | |
| ba0c2b28-6be1-4a44-8eb9-0e643281bd05 Spain | |
| bbfeb42e-5149-4f58-a894-2fc3d610527b Belgium | |
| 1f6a0bde-7782-457b-930c-cc1f7167390b Denmark | |
| fdd5319c-4db6-414b-906a-c19344887512 Bulgaria | |
| fbb74cf5-d315-4961-bfa0-427b894f963f Germany | |
| 65bb56df-8585-425c-ab0f-c3799594bf71 Norway | |
| 957e1ce7-d460-4107-a1e8-dd43cbaab86a Belgium | |
| bbfeb42e-5149-4f58-a894-2fc3d610527b Belgium | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | Z1NREHAD000A000000XX |
| EAN | 8015644760441 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 278 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 18 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 270 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 20 kg |
| Package Level 1 EAN | 8015644760441 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0024 |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Release | Ekip Touch LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |