View larger
1SDA071478R1 ABB E1.2N 1250 Ekip Hi-Touch LSI 4p F F
1SDA071478R1
071478
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for advanced power management, this 1SDA071478R1 ABB E1.2N 1250 Ekip Hi-Touch LSI 4p F F air circuit breaker protects heavy electrical systems against overloads. Such devices are deployed in large commercial and industrial switchboards to maintain continuous uptime and secure power distribution. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: dea55fd8-3147-40a4-9d6d-77adc677b812 China
- Simplified SCIP: ab908345-d9e6-4ce1-86f2-0db0cbcf78b3 Sweden
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANREHBJ200A000000XX
- EAN: 8015644753283
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | dea55fd8-3147-40a4-9d6d-77adc677b812 China |
| Simplified SCIP | ab908345-d9e6-4ce1-86f2-0db0cbcf78b3 Sweden |
| c11ee253-bcf5-40cb-9532-92931faa5429 Greece | |
| 926ad4c3-c7e6-4c63-a0d9-a958556b6b80 Poland | |
| 3bc536d2-d186-4629-8514-99fd25fde1f0 Czech Republic | |
| 60f16b8d-fe87-4ecc-ac58-41cd0bfe9967 Sweden | |
| 272f87e4-0038-46a1-aed9-62e65f4cf7d0 Spain | |
| 93effe15-6ca9-4f18-a5b9-082e9ec06b5b Hungary | |
| ea427456-63a0-4f94-9cd2-10acb4773ebd Belgium | |
| 81c4c248-05f8-4533-91a5-4b44e3a8781b Denmark | |
| 74c06447-c30e-4875-a403-8cc39434300c Germany | |
| 103eab49-3390-4c72-8b84-ca9be334246e Norway | |
| 31bcfb61-d059-4d8a-9c85-134f96a090c2 Croatia | |
| 453fcd76-7f03-4ef0-aa31-1aca92c2ef20 Hungary | |
| 9c8f50a5-fac6-4d2d-a50f-703f17ef71e4 Poland | |
| e8ac6f66-d66a-4d9b-8999-e896c31d6aa3 Estonia | |
| 7f823658-466a-4520-bb02-e6ff80be89f0 Germany | |
| f25f6bac-e1b7-404e-b345-f482acccde87 Bulgaria | |
| f46280ce-8323-4683-80ab-0133ea0732f9 France | |
| e062d38c-ee73-46fd-91ad-d33f9f7e19d5 Germany | |
| 4aa8b635-1590-4b79-8468-b7e236b6fa2b France | |
| c263fff0-ca42-46d8-bca0-6ef0d251db9a Germany | |
| 93a7df4d-2ad2-4699-b309-64f4d037621f Finland | |
| a446034b-2c8f-4c88-89ff-db9f9659e050 Belgium | |
| 167d0b83-d0b7-4372-925b-498c57ceb232 Portugal | |
| 731698f9-a7dc-4821-b799-62ada676b891 Poland | |
| 70acf56a-a235-4578-8f08-45b8fbdbf8f0 Netherlands | |
| 7e4650d5-cc93-475a-a881-79f24acd9934 Germany | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANREHBJ200A000000XX |
| EAN | 8015644753283 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644753283 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 122 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Hi-Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |