View larger
1SDA072821R1 ABB E1.2N 1250 Ekip Dip LI 4p WMP
1SDA072821R1
072821
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB E1.2N 1250 Ekip Dip LI 4p WMP is a withdrawable air circuit breaker designed to provide reliable overload and short-circuit protection in commercial power systems. Facilities utilize four-pole breakers within switchgear assemblies to ensure dependable circuit control and easy maintenance extraction. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 43ce897e-6e2f-4eb7-8884-4516e60bb2d3 India
- Simplified SCIP: a59775f9-b402-4334-9d2e-da84cf9aad00 France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANREHAA000A000000XX
- EAN: 8015644766719
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 43ce897e-6e2f-4eb7-8884-4516e60bb2d3 India |
| Simplified SCIP | a59775f9-b402-4334-9d2e-da84cf9aad00 France |
| f9370a8e-4192-46d0-8036-d7f842e31391 Portugal | |
| cf4a3194-d056-4c46-9bc6-c8c8c83a3c37 Germany | |
| bf37d0b9-5315-49d0-8515-ff5e3aa3e60a Sweden | |
| 63bd09f8-474c-46be-9d6b-affd9b59d59c Germany | |
| 1b79162c-1e92-4f4c-8935-4818ca2bc1be Greece | |
| f47f306b-1535-4aaa-926c-5bc2da9f0ee0 Sweden | |
| d1cdc4ea-3769-45f5-abf7-87cc60d14082 Bulgaria | |
| 9904670d-3a8f-46ea-915f-ec8211919d94 Poland | |
| 1e7b1eb4-919d-469e-ba40-9f97e9b0ac23 France | |
| e4fc5640-4519-4ebd-b5a9-5c68fd24b8a8 Poland | |
| b81b0bd3-8113-4c64-8b0c-6a68c97d808c Netherlands | |
| 10506aaf-08ce-462e-b83b-e4487e6d9610 Czech Republic | |
| 8654696d-12bb-410f-b679-6f6304faa808 Croatia | |
| 645f1558-af00-4899-9e9b-89154e243cb4 Hungary | |
| 339cecce-d5c2-4c16-b0b1-01a49ab55a18 Hungary | |
| 5ba48f3a-d729-4df7-9ab4-2592cd1b599e Estonia | |
| 7384b1fb-947b-4e12-9a33-b71f7e4b5149 Spain | |
| 8800bd8b-0acd-4bb8-a960-b9baad638fd9 Belgium | |
| 457848cc-0d5c-40b4-a2da-34d5cac14b4c Germany | |
| e1441e0f-f0f6-4d2d-8f3d-0fa2c60e9be3 Poland | |
| 888decc7-2a6e-4ea8-93c4-fdff8eeb7f13 Denmark | |
| a7dd3d76-fd37-4058-853b-aaa05be524c0 Germany | |
| 5d8836c6-459a-4d9b-a243-0775d517ade0 Finland | |
| 836f0639-8872-4dc4-bf06-20bc44a62d01 Germany | |
| 5a038c0a-b9e3-40f2-8fe5-62505f58239f Belgium | |
| 2f068ca2-3ab0-48f9-a594-010ddda38a4c Norway | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANREHAA000A000000XX |
| EAN | 8015644766719 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 348 mm |
| Product Net Height | 363.5 mm |
| Product Net Depth / Length | 271 mm |
| Product Net Weight | 20 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 23 kg |
| Package Level 1 EAN | 8015644766719 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| CAD Dimensional Drawing | 1SDH001252R0065 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 6500 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 244 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Dip LI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0103 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |