View larger
1SDA071436R1 ABB E1.2N 1000 Ekip Touch LSIG 4p F F
1SDA071436R1
071436
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
E1.2
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Air circuit breakers like the Abb 1SDA071436R1 E1.2N 1000 Ekip Touch LSIG 4p F F play a vital role in main electrical switchboards by offering precise control and comprehensive fault protection for heavy commercial networks. These components isolate high-capacity electrical paths during maintenance or abnormal surge conditions.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2360
- Environmental Product Declaration - EPD: 9AKK108468A1900
- Extended Product Lifetime: Lifetime Extension Services are Offered
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 76.4 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 3401ea23-d1fd-45af-aee2-99be50b5b99c India
- Simplified SCIP: 308be1fb-00a3-44b7-9715-a1402cc96aaf France
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: ZANQEGBF000A000000XX
- EAN: 8015644752866
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 3401ea23-d1fd-45af-aee2-99be50b5b99c India |
| Simplified SCIP | 308be1fb-00a3-44b7-9715-a1402cc96aaf France |
| 53a9b548-8c5c-427d-8e74-84639278681e Greece | |
| 9df456e7-3aef-4746-9bba-b63b81bc36df Estonia | |
| 0e261c6e-e179-483e-b268-80e322315a11 Bulgaria | |
| b4db28d0-2004-459e-b767-f07654e0e39f Sweden | |
| 80e61d89-5aba-4d13-a1f4-b772760abd3b Sweden | |
| fb5a636f-2c6b-4ab7-8d6b-f4c84fbcf1ba France | |
| 2fa47747-653c-44f3-a955-8c39ecf00605 Poland | |
| 3a8e13db-27ee-424b-aeda-1d40e5c215b2 Germany | |
| 72eca682-119d-40b3-aa86-c48224846b8f Germany | |
| 2d8aa7d8-f496-4d9f-8bbf-bc4dc4765422 Portugal | |
| 7d2bb053-80fe-4908-a1a8-12559583b5fe Belgium | |
| 453f810d-cadf-4b64-bcc3-09a63ff69725 Spain | |
| b75fd234-9752-4877-ab19-4b490c0e4ab8 Hungary | |
| 0f6b930b-68a4-487c-8aa8-dd426f02fca4 Hungary | |
| 60b71161-8600-45e4-9b48-4a7e2bf75726 Poland | |
| 52e97b0e-77d9-49a0-a8db-49367fc98cef Netherlands | |
| f9f360e4-4d99-4fd2-b350-ea08c147d81f Poland | |
| 3d237607-87ef-4304-9acb-a6658b15ce92 Germany | |
| a243adee-8dcb-490e-b711-0fa14576bbd1 Germany | |
| f86a7a88-0644-4f32-823e-754274e5cae7 Croatia | |
| ba7db598-5a35-431e-b2d4-0953e4631520 Finland | |
| 9fee68dd-93fd-4eb1-9dc5-ef853b8d4627 Denmark | |
| 28e1ca3a-ceb5-4581-ac65-3c560abcda78 Germany | |
| 0c29df83-44f1-464d-bac0-bae5bef63a39 Norway | |
| 994516e2-2f50-4046-917b-e0a08c6a689a Belgium | |
| ca17248a-6d94-4d22-ad2a-94697e4348fb Czech Republic | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANQEGBF000A000000XX |
| EAN | 8015644752866 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752866 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 78 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |