View larger
1SDA071435R1
071435
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2360 |
| Environmental Product Declaration - EPD | 9AKK108468A1900 |
| 9AKK108468A3028 | |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 76.4 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 0953df47-96b2-4e46-afc9-07e6e22df654 Italy |
| Simplified SCIP | b7287978-2ebf-4947-8b3d-3efa7a18cd65 Germany |
| 9d5a60a4-f4be-491f-ac29-e3c61b130e46 Germany | |
| bb6a2c30-0d88-4d35-a405-a67051d283f1 France | |
| 656c4cc1-0e10-4786-b4fb-b88cad5d1927 Germany | |
| 8b9733b3-ca98-459f-a031-8db6ee467c09 Denmark | |
| e9960311-5f19-47c2-a846-efece147e4fc Finland | |
| 76b6ea01-af93-49ad-80d2-4ee83dfb0164 Belgium | |
| 769385ab-9764-4f4a-8c48-8a2813535950 Norway | |
| 59bf27df-689a-477e-b152-248938a859ab Poland | |
| 4dbe6e33-d936-48ab-a078-cdf86ff5ac9e Germany | |
| cf7d5033-be7e-4325-a61f-4dc874bdb269 Hungary | |
| 6f278f5a-0ccc-4fb2-a967-5fa5f98c20c7 Netherlands | |
| ee94eb0c-bb29-48ee-9345-806574f78fcd Estonia | |
| a003996f-9792-4f8c-be6e-7717bb31d26d Portugal | |
| f36dfeb3-7f3c-4de3-88e7-6ba60e1437d6 Greece | |
| cb4f015c-653c-4cd0-9ba9-cbd051a6d402 Poland | |
| 4f717165-b39f-4d34-bd56-9d32f53e7b90 Bulgaria | |
| 2615b2d8-52f1-4833-ad21-dde46ceab0ab Sweden | |
| 7f2be7cf-ffd1-4298-b2e9-8b2a99f2558d Poland | |
| ae34f419-f3cc-4a04-83bc-94282d77f473 Czech Republic | |
| 6f41e1ef-4bd7-487d-a75b-66c83dbbc85e Croatia | |
| 45d7d096-d02d-4296-9007-891e37dd6bfb Germany | |
| d6dbed2c-f377-4f05-9da1-0172c137d0fb Sweden | |
| 2c8cf1da-2d32-46d7-957a-b0013e7f4ef3 Belgium | |
| 34dd787a-bc52-490b-8b51-9ab04c4bbd1c France | |
| 6fcfb675-5592-46ee-b2d9-a593ae23c83c Hungary | |
| f6e965cc-970a-4645-b303-a2f3304367d3 Spain | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | ZANQEGBE000A000000XX |
| EAN | 8015644752859 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 296 mm |
| Product Net Depth / Length | 183 mm |
| Product Net Weight | 16 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 350 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 330 mm |
| Package Level 1 Gross Weight | 18 kg |
| Package Level 1 EAN | 8015644752859 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH001252R0042 |
| Technical | |
| Connecting Capacity | 1000 mm² |
| Current Type | AC |
| Electrical Durability | Ue =< 440 V 8000 cycle |
| Ue = 500 ... 690 V 8000 cycle | |
| 30 cycles per hour | |
| Mechanical Durability | 20000 cycle |
| 60 cycles per hour | |
| Neutral Pole Current ([%Iu]) | 100 % |
| Number of Poles | 4P |
| Power Loss | 78 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 50 kA |
| (230 V AC) 50 kA | |
| (380 V AC) 50 kA | |
| (400 V AC) 50 kA | |
| (415 V AC) 50 kA | |
| (440 V AC) 50 kA | |
| (500 V AC) 50 kA | |
| (660 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics) | 100 % |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 50 kA |
| for 3 s 30 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (400 V AC) 66 kA |
| (415 V AC) 66 kA | |
| (440 V AC) 66 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Rated Voltage (Ur) | 690 V |
| Recommended Screw Driver | M12 |
| Release | Ekip Touch LSI |
| Release Type | EL |
| Short-Circuit Performance Level | N |
| Standards | IEC |
| Sub-type | E1.2 |
| Suitable for IT Networks | Yes, 690V |
| Terminal Connection Type | Front |
| Terminal Type | Bolt |
| Tightening Torque | 45 N·m |
| Certificates and Declarations | |
| ATEX Certificate | No certification needed |
| CSA Certificate | No certification needed |
| CSA Certificate (Intrinsic Safe) | No certification needed |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK106713A5546 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| UL Certificate | No certification needed |
| VDE Certificate | No certification needed |
| Mechanical Drawings | 1SDH000999R0101 |
| Wiring Diagram | 1SDM000091R0001 |
| Instructions and Manuals | 1SDH000999R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| IDEA Granular Category Code (IGCC) | 4926 >> Air circuit breakers |
| Object Classification Code | Q |
| UNSPSC | 39121615 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |